Cargando…

Improved simultaneous quantitation of candesartan and hydrochlorthiazide in human plasma by UPLC–MS/MS and its application in bioequivalence studies

A validated ultra-performance liquid chromatography mass spectrometric method (UPLC–MS/MS) was used for the simultaneous quantitation of candesartan (CN) and hydrochlorothiazide (HCT) in human plasma. The analysis was performed on UPLC–MS/MS system using turbo ion spray interface. Negative ions were...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Bhupinder, Lokhandae, Rama S., Dwivedi, Ashish, Sharma, Sandeep, Dubey, Naveen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5761088/
https://www.ncbi.nlm.nih.gov/pubmed/29403876
http://dx.doi.org/10.1016/j.jpha.2013.05.003
_version_ 1783291496746713088
author Singh, Bhupinder
Lokhandae, Rama S.
Dwivedi, Ashish
Sharma, Sandeep
Dubey, Naveen
author_facet Singh, Bhupinder
Lokhandae, Rama S.
Dwivedi, Ashish
Sharma, Sandeep
Dubey, Naveen
author_sort Singh, Bhupinder
collection PubMed
description A validated ultra-performance liquid chromatography mass spectrometric method (UPLC–MS/MS) was used for the simultaneous quantitation of candesartan (CN) and hydrochlorothiazide (HCT) in human plasma. The analysis was performed on UPLC–MS/MS system using turbo ion spray interface. Negative ions were measured in multiple reaction monitoring (MRM) mode. The analytes were extracted using a liquid–liquid extraction (LLE) method by using 0.1 mL of plasma volume. The lower limit of quantitation for CN and HCT was 1.00 ng/mL whereas the upper limit of quantitation was 499.15 ng/mL and 601.61 ng/mL for CN and HCT respectively. CN d(4) and HCT-(13)Cd(2) were used as the internal standards for CN and HCT respectively. The chromatography was achieved within 2.0 min run time using a C18 Phenomenex, Gemini NX (100 mm×4.6 mm, 5 µm) column with organic mixture:buffer solution (80:20, v/v) at a flow rate of 0.800 mL/min. The method has been successfully applied to establish the bioequivalence of candesartan cilexetil (CNC) and HCT immediate release tablets with reference product in human subjects.
format Online
Article
Text
id pubmed-5761088
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-57610882018-02-05 Improved simultaneous quantitation of candesartan and hydrochlorthiazide in human plasma by UPLC–MS/MS and its application in bioequivalence studies Singh, Bhupinder Lokhandae, Rama S. Dwivedi, Ashish Sharma, Sandeep Dubey, Naveen J Pharm Anal Original Article A validated ultra-performance liquid chromatography mass spectrometric method (UPLC–MS/MS) was used for the simultaneous quantitation of candesartan (CN) and hydrochlorothiazide (HCT) in human plasma. The analysis was performed on UPLC–MS/MS system using turbo ion spray interface. Negative ions were measured in multiple reaction monitoring (MRM) mode. The analytes were extracted using a liquid–liquid extraction (LLE) method by using 0.1 mL of plasma volume. The lower limit of quantitation for CN and HCT was 1.00 ng/mL whereas the upper limit of quantitation was 499.15 ng/mL and 601.61 ng/mL for CN and HCT respectively. CN d(4) and HCT-(13)Cd(2) were used as the internal standards for CN and HCT respectively. The chromatography was achieved within 2.0 min run time using a C18 Phenomenex, Gemini NX (100 mm×4.6 mm, 5 µm) column with organic mixture:buffer solution (80:20, v/v) at a flow rate of 0.800 mL/min. The method has been successfully applied to establish the bioequivalence of candesartan cilexetil (CNC) and HCT immediate release tablets with reference product in human subjects. Xi'an Jiaotong University 2014-04 2013-06-19 /pmc/articles/PMC5761088/ /pubmed/29403876 http://dx.doi.org/10.1016/j.jpha.2013.05.003 Text en © 2013 Xi’an Jiaotong University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Original Article
Singh, Bhupinder
Lokhandae, Rama S.
Dwivedi, Ashish
Sharma, Sandeep
Dubey, Naveen
Improved simultaneous quantitation of candesartan and hydrochlorthiazide in human plasma by UPLC–MS/MS and its application in bioequivalence studies
title Improved simultaneous quantitation of candesartan and hydrochlorthiazide in human plasma by UPLC–MS/MS and its application in bioequivalence studies
title_full Improved simultaneous quantitation of candesartan and hydrochlorthiazide in human plasma by UPLC–MS/MS and its application in bioequivalence studies
title_fullStr Improved simultaneous quantitation of candesartan and hydrochlorthiazide in human plasma by UPLC–MS/MS and its application in bioequivalence studies
title_full_unstemmed Improved simultaneous quantitation of candesartan and hydrochlorthiazide in human plasma by UPLC–MS/MS and its application in bioequivalence studies
title_short Improved simultaneous quantitation of candesartan and hydrochlorthiazide in human plasma by UPLC–MS/MS and its application in bioequivalence studies
title_sort improved simultaneous quantitation of candesartan and hydrochlorthiazide in human plasma by uplc–ms/ms and its application in bioequivalence studies
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5761088/
https://www.ncbi.nlm.nih.gov/pubmed/29403876
http://dx.doi.org/10.1016/j.jpha.2013.05.003
work_keys_str_mv AT singhbhupinder improvedsimultaneousquantitationofcandesartanandhydrochlorthiazideinhumanplasmabyuplcmsmsanditsapplicationinbioequivalencestudies
AT lokhandaeramas improvedsimultaneousquantitationofcandesartanandhydrochlorthiazideinhumanplasmabyuplcmsmsanditsapplicationinbioequivalencestudies
AT dwivediashish improvedsimultaneousquantitationofcandesartanandhydrochlorthiazideinhumanplasmabyuplcmsmsanditsapplicationinbioequivalencestudies
AT sharmasandeep improvedsimultaneousquantitationofcandesartanandhydrochlorthiazideinhumanplasmabyuplcmsmsanditsapplicationinbioequivalencestudies
AT dubeynaveen improvedsimultaneousquantitationofcandesartanandhydrochlorthiazideinhumanplasmabyuplcmsmsanditsapplicationinbioequivalencestudies