Cargando…
Determination of atractylon in rat plasma by a GC–MS method and its application to a pharmacokinetic study()
A sensitive and selective method based on gas chromatography hyphenated to mass spectrometry (GC–MS) was developed and validated for the determination of atractylon in rat plasma. Plasma samples were processed by liquid–liquid extraction with ethyl acetate-n-hexane (1:1, v/v) using acetophenone as a...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Xi'an Jiaotong University
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762239/ https://www.ncbi.nlm.nih.gov/pubmed/29403946 http://dx.doi.org/10.1016/j.jpha.2015.03.002 |
_version_ | 1783291646680498176 |
---|---|
author | Yan, Han Sun, Yuanyuan Ma, Yuying Ji, Bin Hou, Xiaohong Yu, Zhiguo Zhao, Yunli |
author_facet | Yan, Han Sun, Yuanyuan Ma, Yuying Ji, Bin Hou, Xiaohong Yu, Zhiguo Zhao, Yunli |
author_sort | Yan, Han |
collection | PubMed |
description | A sensitive and selective method based on gas chromatography hyphenated to mass spectrometry (GC–MS) was developed and validated for the determination of atractylon in rat plasma. Plasma samples were processed by liquid–liquid extraction with ethyl acetate-n-hexane (1:1, v/v) using acetophenone as an internal standard (IS). Analytes were determined in selective ion monitoring (SIM) mode using target ions at m/z 108.1 for atractylon and m/z 105.1 for acetophenone. The calibration curve was linear over the concentration range of 10–1000 ng/mL with lower limit of quantification of 10 ng/mL. The intra- and inter-day precision variations were not more than 10.4% and 9.6%, respectively, whilst accuracy values ranged from −6.5% to 4.9%. Extraction recovery of the assay was satisfactory. This method was successfully applied to quantification and pharmacokinetic study of atractylon in rat plasma after intragastric administration of Atractylodis extract. |
format | Online Article Text |
id | pubmed-5762239 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Xi'an Jiaotong University |
record_format | MEDLINE/PubMed |
spelling | pubmed-57622392018-02-05 Determination of atractylon in rat plasma by a GC–MS method and its application to a pharmacokinetic study() Yan, Han Sun, Yuanyuan Ma, Yuying Ji, Bin Hou, Xiaohong Yu, Zhiguo Zhao, Yunli J Pharm Anal Short Communication A sensitive and selective method based on gas chromatography hyphenated to mass spectrometry (GC–MS) was developed and validated for the determination of atractylon in rat plasma. Plasma samples were processed by liquid–liquid extraction with ethyl acetate-n-hexane (1:1, v/v) using acetophenone as an internal standard (IS). Analytes were determined in selective ion monitoring (SIM) mode using target ions at m/z 108.1 for atractylon and m/z 105.1 for acetophenone. The calibration curve was linear over the concentration range of 10–1000 ng/mL with lower limit of quantification of 10 ng/mL. The intra- and inter-day precision variations were not more than 10.4% and 9.6%, respectively, whilst accuracy values ranged from −6.5% to 4.9%. Extraction recovery of the assay was satisfactory. This method was successfully applied to quantification and pharmacokinetic study of atractylon in rat plasma after intragastric administration of Atractylodis extract. Xi'an Jiaotong University 2015-10 2015-03-28 /pmc/articles/PMC5762239/ /pubmed/29403946 http://dx.doi.org/10.1016/j.jpha.2015.03.002 Text en © 2015 Xi'an Jiaotong University http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Short Communication Yan, Han Sun, Yuanyuan Ma, Yuying Ji, Bin Hou, Xiaohong Yu, Zhiguo Zhao, Yunli Determination of atractylon in rat plasma by a GC–MS method and its application to a pharmacokinetic study() |
title | Determination of atractylon in rat plasma by a GC–MS method and its application to a pharmacokinetic study() |
title_full | Determination of atractylon in rat plasma by a GC–MS method and its application to a pharmacokinetic study() |
title_fullStr | Determination of atractylon in rat plasma by a GC–MS method and its application to a pharmacokinetic study() |
title_full_unstemmed | Determination of atractylon in rat plasma by a GC–MS method and its application to a pharmacokinetic study() |
title_short | Determination of atractylon in rat plasma by a GC–MS method and its application to a pharmacokinetic study() |
title_sort | determination of atractylon in rat plasma by a gc–ms method and its application to a pharmacokinetic study() |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5762239/ https://www.ncbi.nlm.nih.gov/pubmed/29403946 http://dx.doi.org/10.1016/j.jpha.2015.03.002 |
work_keys_str_mv | AT yanhan determinationofatractyloninratplasmabyagcmsmethodanditsapplicationtoapharmacokineticstudy AT sunyuanyuan determinationofatractyloninratplasmabyagcmsmethodanditsapplicationtoapharmacokineticstudy AT mayuying determinationofatractyloninratplasmabyagcmsmethodanditsapplicationtoapharmacokineticstudy AT jibin determinationofatractyloninratplasmabyagcmsmethodanditsapplicationtoapharmacokineticstudy AT houxiaohong determinationofatractyloninratplasmabyagcmsmethodanditsapplicationtoapharmacokineticstudy AT yuzhiguo determinationofatractyloninratplasmabyagcmsmethodanditsapplicationtoapharmacokineticstudy AT zhaoyunli determinationofatractyloninratplasmabyagcmsmethodanditsapplicationtoapharmacokineticstudy |