Cargando…

Application of a validated HPLC-PDA method for the determination of melatonin content and its release from poly(lactic acid) nanoparticles

Melatonin is a natural hormone and with the advancement of age its production declines and thereby may result in some neurological disorders. Exogenous administration of melatonin has been suggested as a neuroprotective agent. Due to its low oral bioavailability, the loading of melatonin in polymeri...

Descripción completa

Detalles Bibliográficos
Autores principales: Martins, Leiziani Gnatkowski, khalil, Najeh Maissar, Mainardes, Rubiana Mara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5790749/
https://www.ncbi.nlm.nih.gov/pubmed/29404064
http://dx.doi.org/10.1016/j.jpha.2017.05.007
_version_ 1783296501928165376
author Martins, Leiziani Gnatkowski
khalil, Najeh Maissar
Mainardes, Rubiana Mara
author_facet Martins, Leiziani Gnatkowski
khalil, Najeh Maissar
Mainardes, Rubiana Mara
author_sort Martins, Leiziani Gnatkowski
collection PubMed
description Melatonin is a natural hormone and with the advancement of age its production declines and thereby may result in some neurological disorders. Exogenous administration of melatonin has been suggested as a neuroprotective agent. Due to its low oral bioavailability, the loading of melatonin in polymeric nanoparticles could be an important tool to effectively use exogenous melatonin. The quantification of the incorporated drug within polymeric nanoparticles is an important step in nanoparticles characterization. An analytical method using high performance liquid chromatography equipped with photodiode array detector (HPLC-PDA) was developed and validated for melatonin determination in poly (lactic acid) nanoparticles obtained by a single emulsion-solvent evaporation technique. The melatonin in vitro release profile also was determined by the HPLC method. Mobile phase consisted of acetonitrile: water (65:35, v/v) pumped at a flow rate of 0.9 mL/min, in the isocratic mode and PDA detector was set at 220 nm. The method was validated in terms of the selectivity, linearity, precision, accuracy, robustness, limits of detection and quantification. Analytical curve was linear over the concentration range of 10–100 μg/mL, and limits of detection and quantification were 25.9 ng/mL and 78.7 ng/mL, respectively. The mean recovery for melatonin was 100.47% (RSD = 1.25%, n = 9). In the intra- and inter-assay, the coefficient of variation was less than 2%. Robustness was proved performing changes in mobile phase, column temperature and flow rate. The method was suitable for the determination of melatonin encapsulation efficiency in poly(lactic acid) nanoparticles and for the evaluation of melatonin in vitro release profile.
format Online
Article
Text
id pubmed-5790749
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-57907492018-02-05 Application of a validated HPLC-PDA method for the determination of melatonin content and its release from poly(lactic acid) nanoparticles Martins, Leiziani Gnatkowski khalil, Najeh Maissar Mainardes, Rubiana Mara J Pharm Anal Original Research Article Melatonin is a natural hormone and with the advancement of age its production declines and thereby may result in some neurological disorders. Exogenous administration of melatonin has been suggested as a neuroprotective agent. Due to its low oral bioavailability, the loading of melatonin in polymeric nanoparticles could be an important tool to effectively use exogenous melatonin. The quantification of the incorporated drug within polymeric nanoparticles is an important step in nanoparticles characterization. An analytical method using high performance liquid chromatography equipped with photodiode array detector (HPLC-PDA) was developed and validated for melatonin determination in poly (lactic acid) nanoparticles obtained by a single emulsion-solvent evaporation technique. The melatonin in vitro release profile also was determined by the HPLC method. Mobile phase consisted of acetonitrile: water (65:35, v/v) pumped at a flow rate of 0.9 mL/min, in the isocratic mode and PDA detector was set at 220 nm. The method was validated in terms of the selectivity, linearity, precision, accuracy, robustness, limits of detection and quantification. Analytical curve was linear over the concentration range of 10–100 μg/mL, and limits of detection and quantification were 25.9 ng/mL and 78.7 ng/mL, respectively. The mean recovery for melatonin was 100.47% (RSD = 1.25%, n = 9). In the intra- and inter-assay, the coefficient of variation was less than 2%. Robustness was proved performing changes in mobile phase, column temperature and flow rate. The method was suitable for the determination of melatonin encapsulation efficiency in poly(lactic acid) nanoparticles and for the evaluation of melatonin in vitro release profile. Xi'an Jiaotong University 2017-12 2017-05-20 /pmc/articles/PMC5790749/ /pubmed/29404064 http://dx.doi.org/10.1016/j.jpha.2017.05.007 Text en © 2017 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Martins, Leiziani Gnatkowski
khalil, Najeh Maissar
Mainardes, Rubiana Mara
Application of a validated HPLC-PDA method for the determination of melatonin content and its release from poly(lactic acid) nanoparticles
title Application of a validated HPLC-PDA method for the determination of melatonin content and its release from poly(lactic acid) nanoparticles
title_full Application of a validated HPLC-PDA method for the determination of melatonin content and its release from poly(lactic acid) nanoparticles
title_fullStr Application of a validated HPLC-PDA method for the determination of melatonin content and its release from poly(lactic acid) nanoparticles
title_full_unstemmed Application of a validated HPLC-PDA method for the determination of melatonin content and its release from poly(lactic acid) nanoparticles
title_short Application of a validated HPLC-PDA method for the determination of melatonin content and its release from poly(lactic acid) nanoparticles
title_sort application of a validated hplc-pda method for the determination of melatonin content and its release from poly(lactic acid) nanoparticles
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5790749/
https://www.ncbi.nlm.nih.gov/pubmed/29404064
http://dx.doi.org/10.1016/j.jpha.2017.05.007
work_keys_str_mv AT martinsleizianignatkowski applicationofavalidatedhplcpdamethodforthedeterminationofmelatonincontentanditsreleasefrompolylacticacidnanoparticles
AT khalilnajehmaissar applicationofavalidatedhplcpdamethodforthedeterminationofmelatonincontentanditsreleasefrompolylacticacidnanoparticles
AT mainardesrubianamara applicationofavalidatedhplcpdamethodforthedeterminationofmelatonincontentanditsreleasefrompolylacticacidnanoparticles