Cargando…
Integrated Temperature and Hydrogen Sensors with MEMS Technology
In this work, a PdNi thin film hydrogen gas sensor with integrated Pt thin film temperature sensor was designed and fabricated using the micro-electro-mechanical system (MEMS) process. The integrated sensors consist of two resistors: the former, based on Pt film, is used as a temperature sensor, whi...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795469/ https://www.ncbi.nlm.nih.gov/pubmed/29301220 http://dx.doi.org/10.3390/s18010094 |
_version_ | 1783297303144038400 |
---|---|
author | Jiang, Hongchuan Huang, Min Yu, Yibing Tian, Xiaoyu Zhao, Xiaohui Zhang, Wanli Zhang, Jianfeng Huang, Yifan Yu, Kun |
author_facet | Jiang, Hongchuan Huang, Min Yu, Yibing Tian, Xiaoyu Zhao, Xiaohui Zhang, Wanli Zhang, Jianfeng Huang, Yifan Yu, Kun |
author_sort | Jiang, Hongchuan |
collection | PubMed |
description | In this work, a PdNi thin film hydrogen gas sensor with integrated Pt thin film temperature sensor was designed and fabricated using the micro-electro-mechanical system (MEMS) process. The integrated sensors consist of two resistors: the former, based on Pt film, is used as a temperature sensor, while the latter had the function of hydrogen sensing and is based on PdNi alloy film. The temperature coefficient of resistance (TCR) in both devices was measured and the output response of the PdNi film hydrogen sensor was calibrated based on the temperature acquired by the Pt temperature sensor. The SiN layer was deposited on top of Pt film to inhibit the hydrogen diffusion and reduce consequent disturbance on temperature measurement. The TCR of the PdNi film and the Pt film was about 0.00122/K and 0.00217/K, respectively. The performances of the PdNi film hydrogen sensor were investigated with hydrogen concentrations from 0.3% to 3% on different temperatures from 294.7 to 302.2 K. With the measured temperature of the Pt resistor and the TCR of the PdNi film, the impact of the temperature on the performances of the PdNi film hydrogen sensor was reduced. The output response, response time and recovery time of the PdNi film hydrogen sensors under the hydrogen concentration of 0.5%, 1.0%, 1.5% and 2.0% were measured at 313 K. The output response of the PdNi thin film hydrogen sensors increased with increasing hydrogen concentration while the response time and recovery time decreased. A cycling test between pure nitrogen and 3% hydrogen concentration was performed at 313 K and PdNi thin film hydrogen sensor demonstrated great repeatability in the cycling test. |
format | Online Article Text |
id | pubmed-5795469 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-57954692018-02-13 Integrated Temperature and Hydrogen Sensors with MEMS Technology Jiang, Hongchuan Huang, Min Yu, Yibing Tian, Xiaoyu Zhao, Xiaohui Zhang, Wanli Zhang, Jianfeng Huang, Yifan Yu, Kun Sensors (Basel) Article In this work, a PdNi thin film hydrogen gas sensor with integrated Pt thin film temperature sensor was designed and fabricated using the micro-electro-mechanical system (MEMS) process. The integrated sensors consist of two resistors: the former, based on Pt film, is used as a temperature sensor, while the latter had the function of hydrogen sensing and is based on PdNi alloy film. The temperature coefficient of resistance (TCR) in both devices was measured and the output response of the PdNi film hydrogen sensor was calibrated based on the temperature acquired by the Pt temperature sensor. The SiN layer was deposited on top of Pt film to inhibit the hydrogen diffusion and reduce consequent disturbance on temperature measurement. The TCR of the PdNi film and the Pt film was about 0.00122/K and 0.00217/K, respectively. The performances of the PdNi film hydrogen sensor were investigated with hydrogen concentrations from 0.3% to 3% on different temperatures from 294.7 to 302.2 K. With the measured temperature of the Pt resistor and the TCR of the PdNi film, the impact of the temperature on the performances of the PdNi film hydrogen sensor was reduced. The output response, response time and recovery time of the PdNi film hydrogen sensors under the hydrogen concentration of 0.5%, 1.0%, 1.5% and 2.0% were measured at 313 K. The output response of the PdNi thin film hydrogen sensors increased with increasing hydrogen concentration while the response time and recovery time decreased. A cycling test between pure nitrogen and 3% hydrogen concentration was performed at 313 K and PdNi thin film hydrogen sensor demonstrated great repeatability in the cycling test. MDPI 2017-12-31 /pmc/articles/PMC5795469/ /pubmed/29301220 http://dx.doi.org/10.3390/s18010094 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jiang, Hongchuan Huang, Min Yu, Yibing Tian, Xiaoyu Zhao, Xiaohui Zhang, Wanli Zhang, Jianfeng Huang, Yifan Yu, Kun Integrated Temperature and Hydrogen Sensors with MEMS Technology |
title | Integrated Temperature and Hydrogen Sensors with MEMS Technology |
title_full | Integrated Temperature and Hydrogen Sensors with MEMS Technology |
title_fullStr | Integrated Temperature and Hydrogen Sensors with MEMS Technology |
title_full_unstemmed | Integrated Temperature and Hydrogen Sensors with MEMS Technology |
title_short | Integrated Temperature and Hydrogen Sensors with MEMS Technology |
title_sort | integrated temperature and hydrogen sensors with mems technology |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795469/ https://www.ncbi.nlm.nih.gov/pubmed/29301220 http://dx.doi.org/10.3390/s18010094 |
work_keys_str_mv | AT jianghongchuan integratedtemperatureandhydrogensensorswithmemstechnology AT huangmin integratedtemperatureandhydrogensensorswithmemstechnology AT yuyibing integratedtemperatureandhydrogensensorswithmemstechnology AT tianxiaoyu integratedtemperatureandhydrogensensorswithmemstechnology AT zhaoxiaohui integratedtemperatureandhydrogensensorswithmemstechnology AT zhangwanli integratedtemperatureandhydrogensensorswithmemstechnology AT zhangjianfeng integratedtemperatureandhydrogensensorswithmemstechnology AT huangyifan integratedtemperatureandhydrogensensorswithmemstechnology AT yukun integratedtemperatureandhydrogensensorswithmemstechnology |