Cargando…

Integrated Temperature and Hydrogen Sensors with MEMS Technology

In this work, a PdNi thin film hydrogen gas sensor with integrated Pt thin film temperature sensor was designed and fabricated using the micro-electro-mechanical system (MEMS) process. The integrated sensors consist of two resistors: the former, based on Pt film, is used as a temperature sensor, whi...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Hongchuan, Huang, Min, Yu, Yibing, Tian, Xiaoyu, Zhao, Xiaohui, Zhang, Wanli, Zhang, Jianfeng, Huang, Yifan, Yu, Kun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795469/
https://www.ncbi.nlm.nih.gov/pubmed/29301220
http://dx.doi.org/10.3390/s18010094
_version_ 1783297303144038400
author Jiang, Hongchuan
Huang, Min
Yu, Yibing
Tian, Xiaoyu
Zhao, Xiaohui
Zhang, Wanli
Zhang, Jianfeng
Huang, Yifan
Yu, Kun
author_facet Jiang, Hongchuan
Huang, Min
Yu, Yibing
Tian, Xiaoyu
Zhao, Xiaohui
Zhang, Wanli
Zhang, Jianfeng
Huang, Yifan
Yu, Kun
author_sort Jiang, Hongchuan
collection PubMed
description In this work, a PdNi thin film hydrogen gas sensor with integrated Pt thin film temperature sensor was designed and fabricated using the micro-electro-mechanical system (MEMS) process. The integrated sensors consist of two resistors: the former, based on Pt film, is used as a temperature sensor, while the latter had the function of hydrogen sensing and is based on PdNi alloy film. The temperature coefficient of resistance (TCR) in both devices was measured and the output response of the PdNi film hydrogen sensor was calibrated based on the temperature acquired by the Pt temperature sensor. The SiN layer was deposited on top of Pt film to inhibit the hydrogen diffusion and reduce consequent disturbance on temperature measurement. The TCR of the PdNi film and the Pt film was about 0.00122/K and 0.00217/K, respectively. The performances of the PdNi film hydrogen sensor were investigated with hydrogen concentrations from 0.3% to 3% on different temperatures from 294.7 to 302.2 K. With the measured temperature of the Pt resistor and the TCR of the PdNi film, the impact of the temperature on the performances of the PdNi film hydrogen sensor was reduced. The output response, response time and recovery time of the PdNi film hydrogen sensors under the hydrogen concentration of 0.5%, 1.0%, 1.5% and 2.0% were measured at 313 K. The output response of the PdNi thin film hydrogen sensors increased with increasing hydrogen concentration while the response time and recovery time decreased. A cycling test between pure nitrogen and 3% hydrogen concentration was performed at 313 K and PdNi thin film hydrogen sensor demonstrated great repeatability in the cycling test.
format Online
Article
Text
id pubmed-5795469
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57954692018-02-13 Integrated Temperature and Hydrogen Sensors with MEMS Technology Jiang, Hongchuan Huang, Min Yu, Yibing Tian, Xiaoyu Zhao, Xiaohui Zhang, Wanli Zhang, Jianfeng Huang, Yifan Yu, Kun Sensors (Basel) Article In this work, a PdNi thin film hydrogen gas sensor with integrated Pt thin film temperature sensor was designed and fabricated using the micro-electro-mechanical system (MEMS) process. The integrated sensors consist of two resistors: the former, based on Pt film, is used as a temperature sensor, while the latter had the function of hydrogen sensing and is based on PdNi alloy film. The temperature coefficient of resistance (TCR) in both devices was measured and the output response of the PdNi film hydrogen sensor was calibrated based on the temperature acquired by the Pt temperature sensor. The SiN layer was deposited on top of Pt film to inhibit the hydrogen diffusion and reduce consequent disturbance on temperature measurement. The TCR of the PdNi film and the Pt film was about 0.00122/K and 0.00217/K, respectively. The performances of the PdNi film hydrogen sensor were investigated with hydrogen concentrations from 0.3% to 3% on different temperatures from 294.7 to 302.2 K. With the measured temperature of the Pt resistor and the TCR of the PdNi film, the impact of the temperature on the performances of the PdNi film hydrogen sensor was reduced. The output response, response time and recovery time of the PdNi film hydrogen sensors under the hydrogen concentration of 0.5%, 1.0%, 1.5% and 2.0% were measured at 313 K. The output response of the PdNi thin film hydrogen sensors increased with increasing hydrogen concentration while the response time and recovery time decreased. A cycling test between pure nitrogen and 3% hydrogen concentration was performed at 313 K and PdNi thin film hydrogen sensor demonstrated great repeatability in the cycling test. MDPI 2017-12-31 /pmc/articles/PMC5795469/ /pubmed/29301220 http://dx.doi.org/10.3390/s18010094 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jiang, Hongchuan
Huang, Min
Yu, Yibing
Tian, Xiaoyu
Zhao, Xiaohui
Zhang, Wanli
Zhang, Jianfeng
Huang, Yifan
Yu, Kun
Integrated Temperature and Hydrogen Sensors with MEMS Technology
title Integrated Temperature and Hydrogen Sensors with MEMS Technology
title_full Integrated Temperature and Hydrogen Sensors with MEMS Technology
title_fullStr Integrated Temperature and Hydrogen Sensors with MEMS Technology
title_full_unstemmed Integrated Temperature and Hydrogen Sensors with MEMS Technology
title_short Integrated Temperature and Hydrogen Sensors with MEMS Technology
title_sort integrated temperature and hydrogen sensors with mems technology
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795469/
https://www.ncbi.nlm.nih.gov/pubmed/29301220
http://dx.doi.org/10.3390/s18010094
work_keys_str_mv AT jianghongchuan integratedtemperatureandhydrogensensorswithmemstechnology
AT huangmin integratedtemperatureandhydrogensensorswithmemstechnology
AT yuyibing integratedtemperatureandhydrogensensorswithmemstechnology
AT tianxiaoyu integratedtemperatureandhydrogensensorswithmemstechnology
AT zhaoxiaohui integratedtemperatureandhydrogensensorswithmemstechnology
AT zhangwanli integratedtemperatureandhydrogensensorswithmemstechnology
AT zhangjianfeng integratedtemperatureandhydrogensensorswithmemstechnology
AT huangyifan integratedtemperatureandhydrogensensorswithmemstechnology
AT yukun integratedtemperatureandhydrogensensorswithmemstechnology