Cargando…
Elevated zinc concentrations in a 5 months old infant: A case report
Pre-analytical errors account for the majority of laboratory-associated errors. In a 5 months old infant hospitalised with lung dysfunction due to prematurity, a routine measurement of zinc revealed an unexpected elevated concentration of 20.2 µmol/L (reference interval 10.0 - 19.0 µmol/L) compared...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Croatian Society of Medical Biochemistry and Laboratory Medicine
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5806619/ https://www.ncbi.nlm.nih.gov/pubmed/29472807 http://dx.doi.org/10.11613/BM.2018.011001 |