Cargando…
An Ultrasound Assessed Extraction Combined with Ion-Pair HPLC Method and Risk Assessment of Nitrite and Nitrate in Cured Meat
An accurate IPC-UV method was developed and validated for the determination of nitrite (NI) and nitrate (NA) in meat products. The best separation was achieved on a phenyl-hexyl column (150 mm × 4.6 mm, 3 µm) with a mobile phase composed of 25% acetonitrile and 75% buffer (2 mM disodium hydrogen pho...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5852839/ https://www.ncbi.nlm.nih.gov/pubmed/29686927 http://dx.doi.org/10.1155/2018/1907151 |
_version_ | 1783306646898868224 |
---|---|
author | Abdulkair, Babiker Yagoub Elzupir, Amin O. Alamer, Abdulaziz S. |
author_facet | Abdulkair, Babiker Yagoub Elzupir, Amin O. Alamer, Abdulaziz S. |
author_sort | Abdulkair, Babiker Yagoub |
collection | PubMed |
description | An accurate IPC-UV method was developed and validated for the determination of nitrite (NI) and nitrate (NA) in meat products. The best separation was achieved on a phenyl-hexyl column (150 mm × 4.6 mm, 3 µm) with a mobile phase composed of 25% acetonitrile and 75% buffer (2 mM disodium hydrogen phosphate and 3 mM tetrabutylammonium bromide, pH = 4). Eluents were monitored at 205 nm. Linearity ranges were 1.86 × 10(−6)–7.5 µg·ml(−1) and 0.09–5.0 µg·ml(−1) for NI and NA, respectively. The correlation coefficients were greater than 0.999 for NI and NA. This method was applied to a number of processed meat products in Riyadh (n = 155). NI ranged from 1.78 to 129.69 mg·kg(−1), and NA ranged from 0.76 to 96.64 mg·kg(−1). Results showed extensive use of NI and NA; however, concentrations were within the legal limit of Saudi Arabia except for one sample. Further, the risk assessment and dietary exposure have been estimated for both NI and NA. |
format | Online Article Text |
id | pubmed-5852839 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-58528392018-04-23 An Ultrasound Assessed Extraction Combined with Ion-Pair HPLC Method and Risk Assessment of Nitrite and Nitrate in Cured Meat Abdulkair, Babiker Yagoub Elzupir, Amin O. Alamer, Abdulaziz S. J Anal Methods Chem Research Article An accurate IPC-UV method was developed and validated for the determination of nitrite (NI) and nitrate (NA) in meat products. The best separation was achieved on a phenyl-hexyl column (150 mm × 4.6 mm, 3 µm) with a mobile phase composed of 25% acetonitrile and 75% buffer (2 mM disodium hydrogen phosphate and 3 mM tetrabutylammonium bromide, pH = 4). Eluents were monitored at 205 nm. Linearity ranges were 1.86 × 10(−6)–7.5 µg·ml(−1) and 0.09–5.0 µg·ml(−1) for NI and NA, respectively. The correlation coefficients were greater than 0.999 for NI and NA. This method was applied to a number of processed meat products in Riyadh (n = 155). NI ranged from 1.78 to 129.69 mg·kg(−1), and NA ranged from 0.76 to 96.64 mg·kg(−1). Results showed extensive use of NI and NA; however, concentrations were within the legal limit of Saudi Arabia except for one sample. Further, the risk assessment and dietary exposure have been estimated for both NI and NA. Hindawi 2018-03-01 /pmc/articles/PMC5852839/ /pubmed/29686927 http://dx.doi.org/10.1155/2018/1907151 Text en Copyright © 2018 Babiker Yagoub Abdulkair et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Abdulkair, Babiker Yagoub Elzupir, Amin O. Alamer, Abdulaziz S. An Ultrasound Assessed Extraction Combined with Ion-Pair HPLC Method and Risk Assessment of Nitrite and Nitrate in Cured Meat |
title | An Ultrasound Assessed Extraction Combined with Ion-Pair HPLC Method and Risk Assessment of Nitrite and Nitrate in Cured Meat |
title_full | An Ultrasound Assessed Extraction Combined with Ion-Pair HPLC Method and Risk Assessment of Nitrite and Nitrate in Cured Meat |
title_fullStr | An Ultrasound Assessed Extraction Combined with Ion-Pair HPLC Method and Risk Assessment of Nitrite and Nitrate in Cured Meat |
title_full_unstemmed | An Ultrasound Assessed Extraction Combined with Ion-Pair HPLC Method and Risk Assessment of Nitrite and Nitrate in Cured Meat |
title_short | An Ultrasound Assessed Extraction Combined with Ion-Pair HPLC Method and Risk Assessment of Nitrite and Nitrate in Cured Meat |
title_sort | ultrasound assessed extraction combined with ion-pair hplc method and risk assessment of nitrite and nitrate in cured meat |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5852839/ https://www.ncbi.nlm.nih.gov/pubmed/29686927 http://dx.doi.org/10.1155/2018/1907151 |
work_keys_str_mv | AT abdulkairbabikeryagoub anultrasoundassessedextractioncombinedwithionpairhplcmethodandriskassessmentofnitriteandnitrateincuredmeat AT elzupiramino anultrasoundassessedextractioncombinedwithionpairhplcmethodandriskassessmentofnitriteandnitrateincuredmeat AT alamerabdulazizs anultrasoundassessedextractioncombinedwithionpairhplcmethodandriskassessmentofnitriteandnitrateincuredmeat AT abdulkairbabikeryagoub ultrasoundassessedextractioncombinedwithionpairhplcmethodandriskassessmentofnitriteandnitrateincuredmeat AT elzupiramino ultrasoundassessedextractioncombinedwithionpairhplcmethodandriskassessmentofnitriteandnitrateincuredmeat AT alamerabdulazizs ultrasoundassessedextractioncombinedwithionpairhplcmethodandriskassessmentofnitriteandnitrateincuredmeat |