Structural Designing of a MEMS Capacitive Accelerometer for Low Temperature Coefficient and High Linearity

The low temperature coefficient and high linearity of the input-output characteristics are both required for high-performance microelectromechanical systems (MEMS) capacitive accelerometers. In this work, a structural designing of a bulk MEMS capacitive accelerometer is developed for both low temper...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Jiangbo, Zhou, Wu, Yu, Huijun, He, Xiaoping, Peng, Peng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855055/
https://www.ncbi.nlm.nih.gov/pubmed/29470398
http://dx.doi.org/10.3390/s18020643
_version_ 1783307024238379008
author He, Jiangbo
Zhou, Wu
Yu, Huijun
He, Xiaoping
Peng, Peng
author_facet He, Jiangbo
Zhou, Wu
Yu, Huijun
He, Xiaoping
Peng, Peng
author_sort He, Jiangbo
collection PubMed
description The low temperature coefficient and high linearity of the input-output characteristics are both required for high-performance microelectromechanical systems (MEMS) capacitive accelerometers. In this work, a structural designing of a bulk MEMS capacitive accelerometer is developed for both low temperature coefficient and high linearity. Firstly, the contrary effect of the wide-narrow gaps ratio (WNGR) on the temperature coefficient of the scale factor (TCSF) and linearity error is discussed. Secondly, the ability of an improved structure that can avoid the contrary effect is illustrated. The improved structure is proposed in our previous work for reducing the temperature coefficient of bias (TCB) and TCSF. Within the improved structure, both the TCSF and linearity error decrease with increasing WNGR. Then, the precise designing of the improved structure is developed for achieving lower TCB, TCSF, and linearity error. Finally, the precise structural designing is experimentally verified.
format Online
Article
Text
id pubmed-5855055
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-58550552018-03-20 Structural Designing of a MEMS Capacitive Accelerometer for Low Temperature Coefficient and High Linearity He, Jiangbo Zhou, Wu Yu, Huijun He, Xiaoping Peng, Peng Sensors (Basel) Article The low temperature coefficient and high linearity of the input-output characteristics are both required for high-performance microelectromechanical systems (MEMS) capacitive accelerometers. In this work, a structural designing of a bulk MEMS capacitive accelerometer is developed for both low temperature coefficient and high linearity. Firstly, the contrary effect of the wide-narrow gaps ratio (WNGR) on the temperature coefficient of the scale factor (TCSF) and linearity error is discussed. Secondly, the ability of an improved structure that can avoid the contrary effect is illustrated. The improved structure is proposed in our previous work for reducing the temperature coefficient of bias (TCB) and TCSF. Within the improved structure, both the TCSF and linearity error decrease with increasing WNGR. Then, the precise designing of the improved structure is developed for achieving lower TCB, TCSF, and linearity error. Finally, the precise structural designing is experimentally verified. MDPI 2018-02-22 /pmc/articles/PMC5855055/ /pubmed/29470398 http://dx.doi.org/10.3390/s18020643 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
He, Jiangbo
Zhou, Wu
Yu, Huijun
He, Xiaoping
Peng, Peng
Structural Designing of a MEMS Capacitive Accelerometer for Low Temperature Coefficient and High Linearity
title Structural Designing of a MEMS Capacitive Accelerometer for Low Temperature Coefficient and High Linearity
title_full Structural Designing of a MEMS Capacitive Accelerometer for Low Temperature Coefficient and High Linearity
title_fullStr Structural Designing of a MEMS Capacitive Accelerometer for Low Temperature Coefficient and High Linearity
title_full_unstemmed Structural Designing of a MEMS Capacitive Accelerometer for Low Temperature Coefficient and High Linearity
title_short Structural Designing of a MEMS Capacitive Accelerometer for Low Temperature Coefficient and High Linearity
title_sort structural designing of a mems capacitive accelerometer for low temperature coefficient and high linearity
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855055/
https://www.ncbi.nlm.nih.gov/pubmed/29470398
http://dx.doi.org/10.3390/s18020643
work_keys_str_mv AT hejiangbo structuraldesigningofamemscapacitiveaccelerometerforlowtemperaturecoefficientandhighlinearity
AT zhouwu structuraldesigningofamemscapacitiveaccelerometerforlowtemperaturecoefficientandhighlinearity
AT yuhuijun structuraldesigningofamemscapacitiveaccelerometerforlowtemperaturecoefficientandhighlinearity
AT hexiaoping structuraldesigningofamemscapacitiveaccelerometerforlowtemperaturecoefficientandhighlinearity
AT pengpeng structuraldesigningofamemscapacitiveaccelerometerforlowtemperaturecoefficientandhighlinearity