Cargando…

High sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections

Flow cytometry is the gold standard in diagnosis of paroxysmal nocturnal hemoglobinuria (PNH) by detecting the absence of glycol-phosphatidyl inositol (GPI)-linked protein expression on granulocyte and monocyte surfaces. However, the current assays are not optimized and require improvement, particul...

Descripción completa

Detalles Bibliográficos
Autores principales: Chan, Ray Chun-Fai, Leung, Richard H., Posadas, Albert, Lorey, Thomas S., Shaw, Allison J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5867464/
https://www.ncbi.nlm.nih.gov/pubmed/29599976
http://dx.doi.org/10.3892/br.2018.1047
_version_ 1783308969809281024
author Chan, Ray Chun-Fai
Leung, Richard H.
Posadas, Albert
Lorey, Thomas S.
Shaw, Allison J.
author_facet Chan, Ray Chun-Fai
Leung, Richard H.
Posadas, Albert
Lorey, Thomas S.
Shaw, Allison J.
author_sort Chan, Ray Chun-Fai
collection PubMed
description Flow cytometry is the gold standard in diagnosis of paroxysmal nocturnal hemoglobinuria (PNH) by detecting the absence of glycol-phosphatidyl inositol (GPI)-linked protein expression on granulocyte and monocyte surfaces. However, the current assays are not optimized and require improvement, particularly in reducing background fluorescence and optimizing sensitivity and specificity. With more fluorochromes available and with advances in instrument engineering, rare populations may be identified with high sensitivity. The present study assessed an 8-color combination of comprehensive GPI-linked markers, namely fluorescein-labeled proaerolysin (FLAER), cluster of differentiation 157 (CD157), CD24 and CD14, and the lineage markers for granulocyte (CD15) and monocyte (CD64) cells to detect PNH clones. Additionally, to optimize the PNH flow assay, a ‘dump’ channel was used, comprised of CD5 and CD19, to exclude non-specific binding in order to reduce background. This method aimed to improve sensitivity and reduce the background to create an optimized PNH flow cocktail. The results demonstrated that the current 4-color PNH combination identifies a CD55(−) and FLAER(+) population that is not PNH clones. By contrast, the 8-color panel delineated PNH clones from both monocyte and granulocytes by using granulocyte antigen (CD15) and monocyte antigen (CD64) as a gating strategy. The sensitivity was 0.01% for granulocytes and 0.05% for monocytes with an acquisition of 100,000 monocyte and granulocyte events. The background on a normal whole blood sample was 0.00076% on monocytes and 0.00277% on granulocytes. Thus, overall, the 8-color PNH assay exhibited high levels of specificity and sensitivity. The 8-color combination facilitated the improvement and enhancement of sensitivity in PNH clone identification, and may provide a useful tool for pathologists in PNH diagnosis and for monitoring patients at risk of developing classical/hemolytic PNH, to enable treatment to be delivered promptly.
format Online
Article
Text
id pubmed-5867464
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-58674642018-03-29 High sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections Chan, Ray Chun-Fai Leung, Richard H. Posadas, Albert Lorey, Thomas S. Shaw, Allison J. Biomed Rep Articles Flow cytometry is the gold standard in diagnosis of paroxysmal nocturnal hemoglobinuria (PNH) by detecting the absence of glycol-phosphatidyl inositol (GPI)-linked protein expression on granulocyte and monocyte surfaces. However, the current assays are not optimized and require improvement, particularly in reducing background fluorescence and optimizing sensitivity and specificity. With more fluorochromes available and with advances in instrument engineering, rare populations may be identified with high sensitivity. The present study assessed an 8-color combination of comprehensive GPI-linked markers, namely fluorescein-labeled proaerolysin (FLAER), cluster of differentiation 157 (CD157), CD24 and CD14, and the lineage markers for granulocyte (CD15) and monocyte (CD64) cells to detect PNH clones. Additionally, to optimize the PNH flow assay, a ‘dump’ channel was used, comprised of CD5 and CD19, to exclude non-specific binding in order to reduce background. This method aimed to improve sensitivity and reduce the background to create an optimized PNH flow cocktail. The results demonstrated that the current 4-color PNH combination identifies a CD55(−) and FLAER(+) population that is not PNH clones. By contrast, the 8-color panel delineated PNH clones from both monocyte and granulocytes by using granulocyte antigen (CD15) and monocyte antigen (CD64) as a gating strategy. The sensitivity was 0.01% for granulocytes and 0.05% for monocytes with an acquisition of 100,000 monocyte and granulocyte events. The background on a normal whole blood sample was 0.00076% on monocytes and 0.00277% on granulocytes. Thus, overall, the 8-color PNH assay exhibited high levels of specificity and sensitivity. The 8-color combination facilitated the improvement and enhancement of sensitivity in PNH clone identification, and may provide a useful tool for pathologists in PNH diagnosis and for monitoring patients at risk of developing classical/hemolytic PNH, to enable treatment to be delivered promptly. D.A. Spandidos 2018-03 2018-01-24 /pmc/articles/PMC5867464/ /pubmed/29599976 http://dx.doi.org/10.3892/br.2018.1047 Text en Copyright: © Chan et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Chan, Ray Chun-Fai
Leung, Richard H.
Posadas, Albert
Lorey, Thomas S.
Shaw, Allison J.
High sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections
title High sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections
title_full High sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections
title_fullStr High sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections
title_full_unstemmed High sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections
title_short High sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections
title_sort high sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5867464/
https://www.ncbi.nlm.nih.gov/pubmed/29599976
http://dx.doi.org/10.3892/br.2018.1047
work_keys_str_mv AT chanraychunfai highsensitivity8colorflowcytometryassayforparoxysmalnocturnalhemoglobinuriagranulocyteandmonocytedetections
AT leungrichardh highsensitivity8colorflowcytometryassayforparoxysmalnocturnalhemoglobinuriagranulocyteandmonocytedetections
AT posadasalbert highsensitivity8colorflowcytometryassayforparoxysmalnocturnalhemoglobinuriagranulocyteandmonocytedetections
AT loreythomass highsensitivity8colorflowcytometryassayforparoxysmalnocturnalhemoglobinuriagranulocyteandmonocytedetections
AT shawallisonj highsensitivity8colorflowcytometryassayforparoxysmalnocturnalhemoglobinuriagranulocyteandmonocytedetections