Implementation of Failure Mode and Effects Analysis to the specimens flow in a population-based colorectal cancer screening programme using immunochemical faecal occult blood tests: a quality improvement project in the Milan colorectal cancer screening programme
BACKGROUND: A multidisciplinary working group applied the Healthcare Failure Mode and Effects Analysis (HFMEA) approach to the flow of kits and specimens for the first-level test of a colorectal cancer screening programme using immunochemical faecal occult blood tests. METHODS: HFMEA comprised four...