Recovery of lost motor evoked potentials in open thoracoabdominal aortic aneurysm repair using intercostal artery bypass
Ischemia of the spinal cord remains a disastrous complication in thoracoabdominal aortic aneurysm (TAAA) surgery. We report a case of open type I TAAA repair during which no motor evoked potentials were detectable for >1 hour after aortic cross-clamping. The creation of three intercostal artery b...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5928281/ https://www.ncbi.nlm.nih.gov/pubmed/29725663 http://dx.doi.org/10.1016/j.jvscit.2017.12.004 |
Sumario: | Ischemia of the spinal cord remains a disastrous complication in thoracoabdominal aortic aneurysm (TAAA) surgery. We report a case of open type I TAAA repair during which no motor evoked potentials were detectable for >1 hour after aortic cross-clamping. The creation of three intercostal artery bypasses restored spinal cord perfusion. As the patient showed only moderate clinical signs of spinal cord ischemia afterward, we underline the role of neuromonitoring to guide intercostal artery bypass implantation during TAAA surgery as the combined use of neuromonitoring and intercostal artery bypass implantation may prevent paraplegia in specific TAAA cases. |
---|