Cargando…

Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients

OBJECTIVE: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. METHODS: From January 2011 to December 2016, 763 patients underwen...

Descripción completa

Detalles Bibliográficos
Autores principales: Mujtaba, Syed Saleem, Ledingham, Simon M., Shah, Asif Raza, Pillay, Thasee, Schueler, Stephan, Clark, Stephen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Cirurgia Cardiovascular 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5985837/
https://www.ncbi.nlm.nih.gov/pubmed/29898140
http://dx.doi.org/10.21470/1678-9741-2017-0088