Cargando…
Bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages
Food quality control is a mandatory task in the food industry and relies on the availability of simple, cost-effective and stable sensing platforms. In the present work, the applicability of bare glassy carbon electrodes for routine analysis of food samples was evaluated as a valid alternative to ch...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5990824/ https://www.ncbi.nlm.nih.gov/pubmed/29892400 http://dx.doi.org/10.1098/rsos.172146 |
_version_ | 1783329659728953344 |
---|---|
author | Redivo, Luca Stredanský, Miroslav De Angelis, Elisabetta Navarini, Luciano Resmini, Marina Švorc, Ĺubomír |
author_facet | Redivo, Luca Stredanský, Miroslav De Angelis, Elisabetta Navarini, Luciano Resmini, Marina Švorc, Ĺubomír |
author_sort | Redivo, Luca |
collection | PubMed |
description | Food quality control is a mandatory task in the food industry and relies on the availability of simple, cost-effective and stable sensing platforms. In the present work, the applicability of bare glassy carbon electrodes for routine analysis of food samples was evaluated as a valid alternative to chromatographic techniques, using caffeine as test analyte. A number of experimental parameters were optimized and a differential pulse voltammetry was applied for quantification experiments. The detection limit was found to be 2 × 10(−5) M (3σ criterion) and repeatability was evaluated by the relative standard deviation of 4.5%. The influence of sugars, and compounds structurally related to caffeine on the current response of caffeine was evaluated and found to have no significant influence on the electrode performance. The suitability of bare carbon electrodes for routine analysis was successfully demonstrated by quantifying caffeine content in seven commercially available drinks and the results were validated using a standard ultra-high performance liquid chromatography method. This work demonstrates that bare glassy carbon electrodes are a simple, reliable and cost-effective platform for rapid analysis of targets such as caffeine in commercial products and they represent therefore a competitive alternative to the existing analytical methodologies for routine food analysis. |
format | Online Article Text |
id | pubmed-5990824 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Royal Society Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-59908242018-06-11 Bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages Redivo, Luca Stredanský, Miroslav De Angelis, Elisabetta Navarini, Luciano Resmini, Marina Švorc, Ĺubomír R Soc Open Sci Chemistry Food quality control is a mandatory task in the food industry and relies on the availability of simple, cost-effective and stable sensing platforms. In the present work, the applicability of bare glassy carbon electrodes for routine analysis of food samples was evaluated as a valid alternative to chromatographic techniques, using caffeine as test analyte. A number of experimental parameters were optimized and a differential pulse voltammetry was applied for quantification experiments. The detection limit was found to be 2 × 10(−5) M (3σ criterion) and repeatability was evaluated by the relative standard deviation of 4.5%. The influence of sugars, and compounds structurally related to caffeine on the current response of caffeine was evaluated and found to have no significant influence on the electrode performance. The suitability of bare carbon electrodes for routine analysis was successfully demonstrated by quantifying caffeine content in seven commercially available drinks and the results were validated using a standard ultra-high performance liquid chromatography method. This work demonstrates that bare glassy carbon electrodes are a simple, reliable and cost-effective platform for rapid analysis of targets such as caffeine in commercial products and they represent therefore a competitive alternative to the existing analytical methodologies for routine food analysis. The Royal Society Publishing 2018-05-02 /pmc/articles/PMC5990824/ /pubmed/29892400 http://dx.doi.org/10.1098/rsos.172146 Text en © 2018 The Authors. http://creativecommons.org/licenses/by/4.0/ Published by the Royal Society under the terms of the Creative Commons Attribution License http://creativecommons.org/licenses/by/4.0/, which permits unrestricted use, provided the original author and source are credited. |
spellingShingle | Chemistry Redivo, Luca Stredanský, Miroslav De Angelis, Elisabetta Navarini, Luciano Resmini, Marina Švorc, Ĺubomír Bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages |
title | Bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages |
title_full | Bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages |
title_fullStr | Bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages |
title_full_unstemmed | Bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages |
title_short | Bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages |
title_sort | bare carbon electrodes as simple and efficient sensors for the quantification of caffeine in commercial beverages |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5990824/ https://www.ncbi.nlm.nih.gov/pubmed/29892400 http://dx.doi.org/10.1098/rsos.172146 |
work_keys_str_mv | AT redivoluca barecarbonelectrodesassimpleandefficientsensorsforthequantificationofcaffeineincommercialbeverages AT stredanskymiroslav barecarbonelectrodesassimpleandefficientsensorsforthequantificationofcaffeineincommercialbeverages AT deangeliselisabetta barecarbonelectrodesassimpleandefficientsensorsforthequantificationofcaffeineincommercialbeverages AT navariniluciano barecarbonelectrodesassimpleandefficientsensorsforthequantificationofcaffeineincommercialbeverages AT resminimarina barecarbonelectrodesassimpleandefficientsensorsforthequantificationofcaffeineincommercialbeverages AT svorclubomir barecarbonelectrodesassimpleandefficientsensorsforthequantificationofcaffeineincommercialbeverages |