Cargando…

Reinforcement of suture lines with aortic eversion in aortic replacement

BACKGROUND: In this study, we describe the technique of eversion of the native aortic tissue to prevent suture line complications, and report on our results with this technique. METHODS: A total of 42 patients who were operated on due to aortic aneurysm were retrospectively assessed. In all patients...

Descripción completa

Detalles Bibliográficos
Autor principal: Erhan, Kaya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Clinics Cardive Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6002793/
https://www.ncbi.nlm.nih.gov/pubmed/29443351
http://dx.doi.org/10.5830/CVJA-2017-008