Sensitive and rapid determination of amantadine without derivatization in human plasma by LC–MS/MS for a bioequivalence study
A highly sensitive, rapid and rugged liquid chromatography-tandem mass spectrometry (LC-ESI-MS/MS) method was developed for reliable estimation of amantadine (AMD), an antiviral drug in human plasma. The analyte and internal standard (IS), amantadine-d6 (AMD-d6), were extracted from 200 µL plasma by...
Autores principales: | Bhadoriya, Abhaysingh, Rathnam, Shivprakash, Dasandi, Bhavesh, Parmar, Dharmesh, Sanyal, Mallika, Shrivastav, Pranav S. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Xi'an Jiaotong University
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6004625/ https://www.ncbi.nlm.nih.gov/pubmed/29922490 http://dx.doi.org/10.1016/j.jpha.2017.10.003 |
Ejemplares similares
-
Quantitation of tadalafil in human plasma using a sensitive and rapid LC-MS/MS method for a bioequivalence study
por: Bhadoriya, Abhaysingh, et al.
Publicado: (2018) -
Simultaneous quantification of prodrug oseltamivir and its metabolite oseltamivir carboxylate in human plasma by LC–MS/MS to support a bioequivalence study
por: Gupta, Ajay, et al.
Publicado: (2013) -
Application of an LC–MS/MS method for the analysis of amlodipine, valsartan and hydrochlorothiazide in polypill for a bioequivalence study
por: Shah, Jaivik V., et al.
Publicado: (2017) -
Determination of ergocalciferol in human plasma after Diels-Alder derivatization by LC–MS/MS and its application to a bioequivalence study
por: Contractor, Pritesh, et al.
Publicado: (2017) -
Highly sensitive LC–MS/MS method to estimate doxepin and its metabolite nordoxepin in human plasma for a bioequivalence study
por: Patel, Nirav P., et al.
Publicado: (2018)