Cargando…
Autonomous multi-joint soft exosuit with augmentation-power-based control parameter tuning reduces energy cost of loaded walking
BACKGROUND: Soft exosuits are a recent approach for assisting human locomotion, which apply assistive torques to the wearer through functional apparel. Over the past few years, there has been growing recognition of the importance of control individualization for such gait assistive devices to maximi...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6044002/ https://www.ncbi.nlm.nih.gov/pubmed/30001726 http://dx.doi.org/10.1186/s12984-018-0410-y |
_version_ | 1783339395069247488 |
---|---|
author | Lee, Sangjun Kim, Jinsoo Baker, Lauren Long, Andrew Karavas, Nikos Menard, Nicolas Galiana, Ignacio Walsh, Conor J. |
author_facet | Lee, Sangjun Kim, Jinsoo Baker, Lauren Long, Andrew Karavas, Nikos Menard, Nicolas Galiana, Ignacio Walsh, Conor J. |
author_sort | Lee, Sangjun |
collection | PubMed |
description | BACKGROUND: Soft exosuits are a recent approach for assisting human locomotion, which apply assistive torques to the wearer through functional apparel. Over the past few years, there has been growing recognition of the importance of control individualization for such gait assistive devices to maximize benefit to the wearer. In this paper, we present an updated version of autonomous multi-joint soft exosuit, including an online parameter tuning method that customizes control parameters for each individual based on positive ankle augmentation power. METHODS: The soft exosuit is designed to assist with plantarflexion, hip flexion, and hip extension while walking. A mobile actuation system is mounted on a military rucksack, and forces generated by the actuation system are transmitted via Bowden cables to the exosuit. The controller performs an iterative force-based position control of the Bowden cables on a step-by-step basis, delivering multi-articular (plantarflexion and hip flexion) assistance during push-off and hip extension assistance in early stance. To individualize the multi-articular assistance, an online parameter tuning method was developed that customizes two control parameters to maximize the positive augmentation power delivered to the ankle. To investigate the metabolic efficacy of the exosuit with wearer-specific parameters, human subject testing was conducted involving walking on a treadmill at 1.50 m s(− 1) carrying a 6.8-kg loaded rucksack. Seven participants underwent the tuning process, and the metabolic cost of loaded walking was measured with and without wearing the exosuit using the individualized control parameters. RESULTS: The online parameter tuning method was capable of customizing the control parameters, creating a positive ankle augmentation power map for each individual. The subject-specific control parameters and resultant assistance profile shapes varied across the study participants. The exosuit with the wearer-specific parameters significantly reduced the metabolic cost of load carriage by 14.88 ± 1.09% (P = 5 × 10(− 5)) compared to walking without wearing the device and by 22.03 ± 2.23% (P = 2 × 10(− 5)) compared to walking with the device unpowered. CONCLUSION: The autonomous multi-joint soft exosuit with subject-specific control parameters tuned based on positive ankle augmentation power demonstrated the ability to improve human walking economy. Future studies will further investigate the effect of the augmentation-power-based control parameter tuning on wearer biomechanics and energetics. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12984-018-0410-y) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6044002 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-60440022018-07-13 Autonomous multi-joint soft exosuit with augmentation-power-based control parameter tuning reduces energy cost of loaded walking Lee, Sangjun Kim, Jinsoo Baker, Lauren Long, Andrew Karavas, Nikos Menard, Nicolas Galiana, Ignacio Walsh, Conor J. J Neuroeng Rehabil Short Report BACKGROUND: Soft exosuits are a recent approach for assisting human locomotion, which apply assistive torques to the wearer through functional apparel. Over the past few years, there has been growing recognition of the importance of control individualization for such gait assistive devices to maximize benefit to the wearer. In this paper, we present an updated version of autonomous multi-joint soft exosuit, including an online parameter tuning method that customizes control parameters for each individual based on positive ankle augmentation power. METHODS: The soft exosuit is designed to assist with plantarflexion, hip flexion, and hip extension while walking. A mobile actuation system is mounted on a military rucksack, and forces generated by the actuation system are transmitted via Bowden cables to the exosuit. The controller performs an iterative force-based position control of the Bowden cables on a step-by-step basis, delivering multi-articular (plantarflexion and hip flexion) assistance during push-off and hip extension assistance in early stance. To individualize the multi-articular assistance, an online parameter tuning method was developed that customizes two control parameters to maximize the positive augmentation power delivered to the ankle. To investigate the metabolic efficacy of the exosuit with wearer-specific parameters, human subject testing was conducted involving walking on a treadmill at 1.50 m s(− 1) carrying a 6.8-kg loaded rucksack. Seven participants underwent the tuning process, and the metabolic cost of loaded walking was measured with and without wearing the exosuit using the individualized control parameters. RESULTS: The online parameter tuning method was capable of customizing the control parameters, creating a positive ankle augmentation power map for each individual. The subject-specific control parameters and resultant assistance profile shapes varied across the study participants. The exosuit with the wearer-specific parameters significantly reduced the metabolic cost of load carriage by 14.88 ± 1.09% (P = 5 × 10(− 5)) compared to walking without wearing the device and by 22.03 ± 2.23% (P = 2 × 10(− 5)) compared to walking with the device unpowered. CONCLUSION: The autonomous multi-joint soft exosuit with subject-specific control parameters tuned based on positive ankle augmentation power demonstrated the ability to improve human walking economy. Future studies will further investigate the effect of the augmentation-power-based control parameter tuning on wearer biomechanics and energetics. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12984-018-0410-y) contains supplementary material, which is available to authorized users. BioMed Central 2018-07-13 /pmc/articles/PMC6044002/ /pubmed/30001726 http://dx.doi.org/10.1186/s12984-018-0410-y Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Short Report Lee, Sangjun Kim, Jinsoo Baker, Lauren Long, Andrew Karavas, Nikos Menard, Nicolas Galiana, Ignacio Walsh, Conor J. Autonomous multi-joint soft exosuit with augmentation-power-based control parameter tuning reduces energy cost of loaded walking |
title | Autonomous multi-joint soft exosuit with augmentation-power-based control parameter tuning reduces energy cost of loaded walking |
title_full | Autonomous multi-joint soft exosuit with augmentation-power-based control parameter tuning reduces energy cost of loaded walking |
title_fullStr | Autonomous multi-joint soft exosuit with augmentation-power-based control parameter tuning reduces energy cost of loaded walking |
title_full_unstemmed | Autonomous multi-joint soft exosuit with augmentation-power-based control parameter tuning reduces energy cost of loaded walking |
title_short | Autonomous multi-joint soft exosuit with augmentation-power-based control parameter tuning reduces energy cost of loaded walking |
title_sort | autonomous multi-joint soft exosuit with augmentation-power-based control parameter tuning reduces energy cost of loaded walking |
topic | Short Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6044002/ https://www.ncbi.nlm.nih.gov/pubmed/30001726 http://dx.doi.org/10.1186/s12984-018-0410-y |
work_keys_str_mv | AT leesangjun autonomousmultijointsoftexosuitwithaugmentationpowerbasedcontrolparametertuningreducesenergycostofloadedwalking AT kimjinsoo autonomousmultijointsoftexosuitwithaugmentationpowerbasedcontrolparametertuningreducesenergycostofloadedwalking AT bakerlauren autonomousmultijointsoftexosuitwithaugmentationpowerbasedcontrolparametertuningreducesenergycostofloadedwalking AT longandrew autonomousmultijointsoftexosuitwithaugmentationpowerbasedcontrolparametertuningreducesenergycostofloadedwalking AT karavasnikos autonomousmultijointsoftexosuitwithaugmentationpowerbasedcontrolparametertuningreducesenergycostofloadedwalking AT menardnicolas autonomousmultijointsoftexosuitwithaugmentationpowerbasedcontrolparametertuningreducesenergycostofloadedwalking AT galianaignacio autonomousmultijointsoftexosuitwithaugmentationpowerbasedcontrolparametertuningreducesenergycostofloadedwalking AT walshconorj autonomousmultijointsoftexosuitwithaugmentationpowerbasedcontrolparametertuningreducesenergycostofloadedwalking |