Cargando…
Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia
PURPOSE: To investigate two-year outcomes of Visian Implantable Collamer Lens with a central hole (ICL V4c) implantation for correcting high myopia. METHODS: Sixty-one eyes of 32 patients went through ICL V4c implantation. Safety, efficacy, predictability, and intraocular pressure were evaluated 2 y...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6051026/ https://www.ncbi.nlm.nih.gov/pubmed/30057804 http://dx.doi.org/10.1155/2018/8678352 |
_version_ | 1783340438136029184 |
---|---|
author | Yan, Zhipeng Miao, Huamao Zhao, Feng Wang, Xiaoying Chen, Xun Li, Meiyan Zhou, Xingtao |
author_facet | Yan, Zhipeng Miao, Huamao Zhao, Feng Wang, Xiaoying Chen, Xun Li, Meiyan Zhou, Xingtao |
author_sort | Yan, Zhipeng |
collection | PubMed |
description | PURPOSE: To investigate two-year outcomes of Visian Implantable Collamer Lens with a central hole (ICL V4c) implantation for correcting high myopia. METHODS: Sixty-one eyes of 32 patients went through ICL V4c implantation. Safety, efficacy, predictability, and intraocular pressure were evaluated 2 years postoperatively. Anterior chamber volume (ACV), anterior chamber depth (ACD), anterior chamber angle width (ACAW), and vault were measured using a Scheimpflug tomography imaging system. RESULTS: At 2 years, the spherical equivalent refraction decreased from preoperative −14.62 ± 4.29 D to −0.90 ± 0.95 D, with 79% of the eyes within ±0.50 D and 98% within ±1.00 D of the intended correction. The efficacy index was 1.03 ± 0.23, and the safety index was 1.24 ± 0.26. Corrected distance visual acuity (CDVA) remained unchanged in 23% of the eyes, 75% gained one or more lines of CDVA, and 2% lost one line. The ACV, ACD, and ACAW, respectively, decreased from 193.28 ± 29.15 mm(3), 3.15 ± 0.23 mm, and 36.51 ± 6.54 degree to 112.48 ± 17.01 mm(3), 2.99 ± 0.23 mm, and 22.54 ± 5.27 degree (p=0.0008, 0.008, and 0.0003, resp.). Intraocular pressure was 15.39 ± 2.88 mmHg before surgery and was 15.86 ± 4.11 mmHg at 2 years (p=0.11). CONCLUSION: Implantation of ICL V4c is a safe, effective, and predictable procedure for correcting high myopia. Reduction of anterior chamber space after surgery did not induce intraocular pressure increase during the 2-year follow-up. |
format | Online Article Text |
id | pubmed-6051026 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-60510262018-07-29 Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia Yan, Zhipeng Miao, Huamao Zhao, Feng Wang, Xiaoying Chen, Xun Li, Meiyan Zhou, Xingtao J Ophthalmol Clinical Study PURPOSE: To investigate two-year outcomes of Visian Implantable Collamer Lens with a central hole (ICL V4c) implantation for correcting high myopia. METHODS: Sixty-one eyes of 32 patients went through ICL V4c implantation. Safety, efficacy, predictability, and intraocular pressure were evaluated 2 years postoperatively. Anterior chamber volume (ACV), anterior chamber depth (ACD), anterior chamber angle width (ACAW), and vault were measured using a Scheimpflug tomography imaging system. RESULTS: At 2 years, the spherical equivalent refraction decreased from preoperative −14.62 ± 4.29 D to −0.90 ± 0.95 D, with 79% of the eyes within ±0.50 D and 98% within ±1.00 D of the intended correction. The efficacy index was 1.03 ± 0.23, and the safety index was 1.24 ± 0.26. Corrected distance visual acuity (CDVA) remained unchanged in 23% of the eyes, 75% gained one or more lines of CDVA, and 2% lost one line. The ACV, ACD, and ACAW, respectively, decreased from 193.28 ± 29.15 mm(3), 3.15 ± 0.23 mm, and 36.51 ± 6.54 degree to 112.48 ± 17.01 mm(3), 2.99 ± 0.23 mm, and 22.54 ± 5.27 degree (p=0.0008, 0.008, and 0.0003, resp.). Intraocular pressure was 15.39 ± 2.88 mmHg before surgery and was 15.86 ± 4.11 mmHg at 2 years (p=0.11). CONCLUSION: Implantation of ICL V4c is a safe, effective, and predictable procedure for correcting high myopia. Reduction of anterior chamber space after surgery did not induce intraocular pressure increase during the 2-year follow-up. Hindawi 2018-07-03 /pmc/articles/PMC6051026/ /pubmed/30057804 http://dx.doi.org/10.1155/2018/8678352 Text en Copyright © 2018 Zhipeng Yan et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Yan, Zhipeng Miao, Huamao Zhao, Feng Wang, Xiaoying Chen, Xun Li, Meiyan Zhou, Xingtao Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia |
title | Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia |
title_full | Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia |
title_fullStr | Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia |
title_full_unstemmed | Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia |
title_short | Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia |
title_sort | two-year outcomes of visian implantable collamer lens with a central hole for correcting high myopia |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6051026/ https://www.ncbi.nlm.nih.gov/pubmed/30057804 http://dx.doi.org/10.1155/2018/8678352 |
work_keys_str_mv | AT yanzhipeng twoyearoutcomesofvisianimplantablecollamerlenswithacentralholeforcorrectinghighmyopia AT miaohuamao twoyearoutcomesofvisianimplantablecollamerlenswithacentralholeforcorrectinghighmyopia AT zhaofeng twoyearoutcomesofvisianimplantablecollamerlenswithacentralholeforcorrectinghighmyopia AT wangxiaoying twoyearoutcomesofvisianimplantablecollamerlenswithacentralholeforcorrectinghighmyopia AT chenxun twoyearoutcomesofvisianimplantablecollamerlenswithacentralholeforcorrectinghighmyopia AT limeiyan twoyearoutcomesofvisianimplantablecollamerlenswithacentralholeforcorrectinghighmyopia AT zhouxingtao twoyearoutcomesofvisianimplantablecollamerlenswithacentralholeforcorrectinghighmyopia |