Cargando…
Design and Evaluation of FBG-Based Tension Sensor in Laparoscope Surgical Robots
Due to the narrow space and a harsh chemical environment in the sterilization processes for the end-effector of surgical robots, it is difficult to install and integrate suitable sensors for the purpose of effective and precise force control. This paper presents an innovative tension sensor for esti...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068875/ https://www.ncbi.nlm.nih.gov/pubmed/29958441 http://dx.doi.org/10.3390/s18072067 |
_version_ | 1783343367041581056 |
---|---|
author | Xue, Renfeng Ren, Bingyin Huang, Jiaqing Yan, Zhiyuan Du, Zhijiang |
author_facet | Xue, Renfeng Ren, Bingyin Huang, Jiaqing Yan, Zhiyuan Du, Zhijiang |
author_sort | Xue, Renfeng |
collection | PubMed |
description | Due to the narrow space and a harsh chemical environment in the sterilization processes for the end-effector of surgical robots, it is difficult to install and integrate suitable sensors for the purpose of effective and precise force control. This paper presents an innovative tension sensor for estimation of grasping force in our laparoscope surgical robot. The proposed sensor measures the tension of cable using fiber gratings (FBGs) which are pasted in the grooves on the inclined cantilevers of the sensor. By exploiting the stain measurement characteristics of FBGs, the small deformation of the inclined cantilevers caused by the cable tension can be measured. The working principle and the sensor model are analyzed. Based on the sensor model, the dimensions of the sensor are designed and optimized. A dedicated experimental setup is established to calibrate and test the sensor. The results of experiments for estimation the grasping force validate the sensor. |
format | Online Article Text |
id | pubmed-6068875 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-60688752018-08-07 Design and Evaluation of FBG-Based Tension Sensor in Laparoscope Surgical Robots Xue, Renfeng Ren, Bingyin Huang, Jiaqing Yan, Zhiyuan Du, Zhijiang Sensors (Basel) Article Due to the narrow space and a harsh chemical environment in the sterilization processes for the end-effector of surgical robots, it is difficult to install and integrate suitable sensors for the purpose of effective and precise force control. This paper presents an innovative tension sensor for estimation of grasping force in our laparoscope surgical robot. The proposed sensor measures the tension of cable using fiber gratings (FBGs) which are pasted in the grooves on the inclined cantilevers of the sensor. By exploiting the stain measurement characteristics of FBGs, the small deformation of the inclined cantilevers caused by the cable tension can be measured. The working principle and the sensor model are analyzed. Based on the sensor model, the dimensions of the sensor are designed and optimized. A dedicated experimental setup is established to calibrate and test the sensor. The results of experiments for estimation the grasping force validate the sensor. MDPI 2018-06-28 /pmc/articles/PMC6068875/ /pubmed/29958441 http://dx.doi.org/10.3390/s18072067 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Xue, Renfeng Ren, Bingyin Huang, Jiaqing Yan, Zhiyuan Du, Zhijiang Design and Evaluation of FBG-Based Tension Sensor in Laparoscope Surgical Robots |
title | Design and Evaluation of FBG-Based Tension Sensor in Laparoscope Surgical Robots |
title_full | Design and Evaluation of FBG-Based Tension Sensor in Laparoscope Surgical Robots |
title_fullStr | Design and Evaluation of FBG-Based Tension Sensor in Laparoscope Surgical Robots |
title_full_unstemmed | Design and Evaluation of FBG-Based Tension Sensor in Laparoscope Surgical Robots |
title_short | Design and Evaluation of FBG-Based Tension Sensor in Laparoscope Surgical Robots |
title_sort | design and evaluation of fbg-based tension sensor in laparoscope surgical robots |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6068875/ https://www.ncbi.nlm.nih.gov/pubmed/29958441 http://dx.doi.org/10.3390/s18072067 |
work_keys_str_mv | AT xuerenfeng designandevaluationoffbgbasedtensionsensorinlaparoscopesurgicalrobots AT renbingyin designandevaluationoffbgbasedtensionsensorinlaparoscopesurgicalrobots AT huangjiaqing designandevaluationoffbgbasedtensionsensorinlaparoscopesurgicalrobots AT yanzhiyuan designandevaluationoffbgbasedtensionsensorinlaparoscopesurgicalrobots AT duzhijiang designandevaluationoffbgbasedtensionsensorinlaparoscopesurgicalrobots |