Transpalpebral Electrical Stimulation as a Novel Therapeutic Approach to Decrease Intraocular Pressure for Open-Angle Glaucoma: A Pilot Study

PURPOSE: To determine the effect on intraocular pressure of transpalpebral specific exogenous voltages in a cohort of open-angle glaucoma patients. METHODS: This is a prospective, comparative, and experimental pilot study. The electrical stimuli applied consisted of 10 Hz, biphasic, nonrectangular c...