Cargando…
Assessing the capability of Fourier transform infrared spectroscopy in tandem with chemometric analysis for predicting poultry meat spoilage
BACKGROUND: Use of traditional methods for determining meat spoilage is quite laborious and time consuming. Therefore, alternative approaches are needed that can predict the spoilage of meat in a rapid, non-invasive and more elaborative way. In this regard, the spectroscopic techniques have shown th...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PeerJ Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6084285/ https://www.ncbi.nlm.nih.gov/pubmed/30123708 http://dx.doi.org/10.7717/peerj.5376 |
_version_ | 1783346146307997696 |
---|---|
author | Rahman, Ubaid ur Sahar, Amna Pasha, Imran Rahman, Sajjad ur Ishaq, Anum |
author_facet | Rahman, Ubaid ur Sahar, Amna Pasha, Imran Rahman, Sajjad ur Ishaq, Anum |
author_sort | Rahman, Ubaid ur |
collection | PubMed |
description | BACKGROUND: Use of traditional methods for determining meat spoilage is quite laborious and time consuming. Therefore, alternative approaches are needed that can predict the spoilage of meat in a rapid, non-invasive and more elaborative way. In this regard, the spectroscopic techniques have shown their potential for predicting the microbial spoilage of meat-based products. Consequently, the present work was aimed to demonstrate the competence of Fourier transform infrared spectroscopy (FTIR) to detect spoilage in chicken fillets stored under aerobic refrigerated conditions. METHODS: This study was conducted under controlled randomized design (CRD). Chicken samples were stored for 8 days at 4 + 0.5 °C and FTIR spectra were collected at regular intervals (after every 2 days) directly from the sample surface using attenuated total reflectance during the study period. Additionally, total plate count (TPC), Entetobacteriaceae count, pH, CTn (Color transmittance number) color analysis, TVBN (total volatile basic nitrogen) contents, and shear force values were also measured through traditional approaches. FTIR spectral data were interpreted through principal component analysis (PCA) and partial least square (PLS) regression and compared with results of traditional methods for precise estimation of spoilage. RESULTS: Results of TPC (3.04–8.20 CFU/cm(2)), Entetobacteriaceae counts (2.39–6.33 CFU/cm(2)), pH (4.65–7.05), color (57.00–142.00 CTn), TVBN values (6.72–33.60 mg/100 g) and shear force values (8.99–39.23) were measured through traditional methods and compared with FTIR spectral data. Analysis of variance (ANOVA) was applied on data obtained through microbial and quality analyses and results revealed significant changes (P < 0.05) in the values of microbial load and quality parameters of chicken fillets during the storage. FTIR spectra were collected and PCA was applied to illuminate the wavenumbers potentially correlated to the spoilage of meat. PLS regression analysis permitted the estimates of microbial spoilage and quality parameters from the spectra with a fit of R(2) = 0.66 for TPC, R(2) = 0.52 for Entetobacteriaceae numbers and R(2) = 0.56 for TVBN analysis of stored broiler meat. DISCUSSION: PLS regression was applied for quantitative interpretation of spectra, which allowed estimates of microbial loads on chicken surfaces during the storage period. The results suggest that FTIR spectra retain information regarding the spoilage of poultry meat. CONCLUSION: The present work concluded that FTIR spectroscopy coupled with multivariate analysis can be successfully used for quantitative determination of poultry meat spoilage. |
format | Online Article Text |
id | pubmed-6084285 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | PeerJ Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-60842852018-08-17 Assessing the capability of Fourier transform infrared spectroscopy in tandem with chemometric analysis for predicting poultry meat spoilage Rahman, Ubaid ur Sahar, Amna Pasha, Imran Rahman, Sajjad ur Ishaq, Anum PeerJ Agricultural Science BACKGROUND: Use of traditional methods for determining meat spoilage is quite laborious and time consuming. Therefore, alternative approaches are needed that can predict the spoilage of meat in a rapid, non-invasive and more elaborative way. In this regard, the spectroscopic techniques have shown their potential for predicting the microbial spoilage of meat-based products. Consequently, the present work was aimed to demonstrate the competence of Fourier transform infrared spectroscopy (FTIR) to detect spoilage in chicken fillets stored under aerobic refrigerated conditions. METHODS: This study was conducted under controlled randomized design (CRD). Chicken samples were stored for 8 days at 4 + 0.5 °C and FTIR spectra were collected at regular intervals (after every 2 days) directly from the sample surface using attenuated total reflectance during the study period. Additionally, total plate count (TPC), Entetobacteriaceae count, pH, CTn (Color transmittance number) color analysis, TVBN (total volatile basic nitrogen) contents, and shear force values were also measured through traditional approaches. FTIR spectral data were interpreted through principal component analysis (PCA) and partial least square (PLS) regression and compared with results of traditional methods for precise estimation of spoilage. RESULTS: Results of TPC (3.04–8.20 CFU/cm(2)), Entetobacteriaceae counts (2.39–6.33 CFU/cm(2)), pH (4.65–7.05), color (57.00–142.00 CTn), TVBN values (6.72–33.60 mg/100 g) and shear force values (8.99–39.23) were measured through traditional methods and compared with FTIR spectral data. Analysis of variance (ANOVA) was applied on data obtained through microbial and quality analyses and results revealed significant changes (P < 0.05) in the values of microbial load and quality parameters of chicken fillets during the storage. FTIR spectra were collected and PCA was applied to illuminate the wavenumbers potentially correlated to the spoilage of meat. PLS regression analysis permitted the estimates of microbial spoilage and quality parameters from the spectra with a fit of R(2) = 0.66 for TPC, R(2) = 0.52 for Entetobacteriaceae numbers and R(2) = 0.56 for TVBN analysis of stored broiler meat. DISCUSSION: PLS regression was applied for quantitative interpretation of spectra, which allowed estimates of microbial loads on chicken surfaces during the storage period. The results suggest that FTIR spectra retain information regarding the spoilage of poultry meat. CONCLUSION: The present work concluded that FTIR spectroscopy coupled with multivariate analysis can be successfully used for quantitative determination of poultry meat spoilage. PeerJ Inc. 2018-08-06 /pmc/articles/PMC6084285/ /pubmed/30123708 http://dx.doi.org/10.7717/peerj.5376 Text en ©2018 Rahman et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. |
spellingShingle | Agricultural Science Rahman, Ubaid ur Sahar, Amna Pasha, Imran Rahman, Sajjad ur Ishaq, Anum Assessing the capability of Fourier transform infrared spectroscopy in tandem with chemometric analysis for predicting poultry meat spoilage |
title | Assessing the capability of Fourier transform infrared spectroscopy in tandem with chemometric analysis for predicting poultry meat spoilage |
title_full | Assessing the capability of Fourier transform infrared spectroscopy in tandem with chemometric analysis for predicting poultry meat spoilage |
title_fullStr | Assessing the capability of Fourier transform infrared spectroscopy in tandem with chemometric analysis for predicting poultry meat spoilage |
title_full_unstemmed | Assessing the capability of Fourier transform infrared spectroscopy in tandem with chemometric analysis for predicting poultry meat spoilage |
title_short | Assessing the capability of Fourier transform infrared spectroscopy in tandem with chemometric analysis for predicting poultry meat spoilage |
title_sort | assessing the capability of fourier transform infrared spectroscopy in tandem with chemometric analysis for predicting poultry meat spoilage |
topic | Agricultural Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6084285/ https://www.ncbi.nlm.nih.gov/pubmed/30123708 http://dx.doi.org/10.7717/peerj.5376 |
work_keys_str_mv | AT rahmanubaidur assessingthecapabilityoffouriertransforminfraredspectroscopyintandemwithchemometricanalysisforpredictingpoultrymeatspoilage AT saharamna assessingthecapabilityoffouriertransforminfraredspectroscopyintandemwithchemometricanalysisforpredictingpoultrymeatspoilage AT pashaimran assessingthecapabilityoffouriertransforminfraredspectroscopyintandemwithchemometricanalysisforpredictingpoultrymeatspoilage AT rahmansajjadur assessingthecapabilityoffouriertransforminfraredspectroscopyintandemwithchemometricanalysisforpredictingpoultrymeatspoilage AT ishaqanum assessingthecapabilityoffouriertransforminfraredspectroscopyintandemwithchemometricanalysisforpredictingpoultrymeatspoilage |