Cargando…

Automated fluorescence intensity and gradient analysis enables detection of rare fluorescent mutant cells deep within the tissue of RaDR mice

Homologous recombination (HR) events are key drivers of cancer-promoting mutations, and the ability to visualize these events in situ provides important information regarding mutant cell type, location, and clonal expansion. We have previously created the Rosa26 Direct Repeat (RaDR) mouse model wher...

Descripción completa

Detalles Bibliográficos
Autores principales: Wadduwage, Dushan N., Kay, Jennifer, Singh, Vijay Raj, Kiraly, Orsolya, Sukup-Jackson, Michelle R., Rajapakse, Jagath, Engelward, Bevin P., So, Peter T. C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6092416/
https://www.ncbi.nlm.nih.gov/pubmed/30108260
http://dx.doi.org/10.1038/s41598-018-30557-9
_version_ 1783347519404638208
author Wadduwage, Dushan N.
Kay, Jennifer
Singh, Vijay Raj
Kiraly, Orsolya
Sukup-Jackson, Michelle R.
Rajapakse, Jagath
Engelward, Bevin P.
So, Peter T. C.
author_facet Wadduwage, Dushan N.
Kay, Jennifer
Singh, Vijay Raj
Kiraly, Orsolya
Sukup-Jackson, Michelle R.
Rajapakse, Jagath
Engelward, Bevin P.
So, Peter T. C.
author_sort Wadduwage, Dushan N.
collection PubMed
description Homologous recombination (HR) events are key drivers of cancer-promoting mutations, and the ability to visualize these events in situ provides important information regarding mutant cell type, location, and clonal expansion. We have previously created the Rosa26 Direct Repeat (RaDR) mouse model wherein HR at an integrated substrate gives rise to a fluorescent cell. To fully leverage this in situ approach, we need better ways to quantify rare fluorescent cells deep within tissues. Here, we present a robust, automated event quantification algorithm that uses image intensity and gradient features to detect fluorescent cells in deep tissue specimens. To analyze the performance of our algorithm, we simulate fluorescence behavior in tissue using Monte Carlo methods. Importantly, this approach reduces the potential for bias in manual counting and enables quantification of samples with highly dense HR events. Using this approach, we measured the relative frequency of HR within a chromosome and between chromosomes and found that HR within a chromosome is more frequent, which is consistent with the close proximity of sister chromatids. Our approach is both objective and highly rapid, providing a powerful tool, not only to researchers interested in HR, but also to many other researchers who are similarly using fluorescence as a marker for understanding mammalian biology in tissues.
format Online
Article
Text
id pubmed-6092416
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-60924162018-08-20 Automated fluorescence intensity and gradient analysis enables detection of rare fluorescent mutant cells deep within the tissue of RaDR mice Wadduwage, Dushan N. Kay, Jennifer Singh, Vijay Raj Kiraly, Orsolya Sukup-Jackson, Michelle R. Rajapakse, Jagath Engelward, Bevin P. So, Peter T. C. Sci Rep Article Homologous recombination (HR) events are key drivers of cancer-promoting mutations, and the ability to visualize these events in situ provides important information regarding mutant cell type, location, and clonal expansion. We have previously created the Rosa26 Direct Repeat (RaDR) mouse model wherein HR at an integrated substrate gives rise to a fluorescent cell. To fully leverage this in situ approach, we need better ways to quantify rare fluorescent cells deep within tissues. Here, we present a robust, automated event quantification algorithm that uses image intensity and gradient features to detect fluorescent cells in deep tissue specimens. To analyze the performance of our algorithm, we simulate fluorescence behavior in tissue using Monte Carlo methods. Importantly, this approach reduces the potential for bias in manual counting and enables quantification of samples with highly dense HR events. Using this approach, we measured the relative frequency of HR within a chromosome and between chromosomes and found that HR within a chromosome is more frequent, which is consistent with the close proximity of sister chromatids. Our approach is both objective and highly rapid, providing a powerful tool, not only to researchers interested in HR, but also to many other researchers who are similarly using fluorescence as a marker for understanding mammalian biology in tissues. Nature Publishing Group UK 2018-08-14 /pmc/articles/PMC6092416/ /pubmed/30108260 http://dx.doi.org/10.1038/s41598-018-30557-9 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Wadduwage, Dushan N.
Kay, Jennifer
Singh, Vijay Raj
Kiraly, Orsolya
Sukup-Jackson, Michelle R.
Rajapakse, Jagath
Engelward, Bevin P.
So, Peter T. C.
Automated fluorescence intensity and gradient analysis enables detection of rare fluorescent mutant cells deep within the tissue of RaDR mice
title Automated fluorescence intensity and gradient analysis enables detection of rare fluorescent mutant cells deep within the tissue of RaDR mice
title_full Automated fluorescence intensity and gradient analysis enables detection of rare fluorescent mutant cells deep within the tissue of RaDR mice
title_fullStr Automated fluorescence intensity and gradient analysis enables detection of rare fluorescent mutant cells deep within the tissue of RaDR mice
title_full_unstemmed Automated fluorescence intensity and gradient analysis enables detection of rare fluorescent mutant cells deep within the tissue of RaDR mice
title_short Automated fluorescence intensity and gradient analysis enables detection of rare fluorescent mutant cells deep within the tissue of RaDR mice
title_sort automated fluorescence intensity and gradient analysis enables detection of rare fluorescent mutant cells deep within the tissue of radr mice
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6092416/
https://www.ncbi.nlm.nih.gov/pubmed/30108260
http://dx.doi.org/10.1038/s41598-018-30557-9
work_keys_str_mv AT wadduwagedushann automatedfluorescenceintensityandgradientanalysisenablesdetectionofrarefluorescentmutantcellsdeepwithinthetissueofradrmice
AT kayjennifer automatedfluorescenceintensityandgradientanalysisenablesdetectionofrarefluorescentmutantcellsdeepwithinthetissueofradrmice
AT singhvijayraj automatedfluorescenceintensityandgradientanalysisenablesdetectionofrarefluorescentmutantcellsdeepwithinthetissueofradrmice
AT kiralyorsolya automatedfluorescenceintensityandgradientanalysisenablesdetectionofrarefluorescentmutantcellsdeepwithinthetissueofradrmice
AT sukupjacksonmicheller automatedfluorescenceintensityandgradientanalysisenablesdetectionofrarefluorescentmutantcellsdeepwithinthetissueofradrmice
AT rajapaksejagath automatedfluorescenceintensityandgradientanalysisenablesdetectionofrarefluorescentmutantcellsdeepwithinthetissueofradrmice
AT engelwardbevinp automatedfluorescenceintensityandgradientanalysisenablesdetectionofrarefluorescentmutantcellsdeepwithinthetissueofradrmice
AT sopetertc automatedfluorescenceintensityandgradientanalysisenablesdetectionofrarefluorescentmutantcellsdeepwithinthetissueofradrmice