Cargando…

Accurate Measurements of Wall Shear Stress on a Plate with Elliptic Leading Edge

A micro-floating element wall shear stress sensor with backside connections has been developed for accurate measurements of wall shear stress under the turbulent boundary layer. The micro-sensor was designed and fabricated on a 10.16 cm SOI (Silicon on Insulator) wafer by MEMS (Micro-Electro-Mechani...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Guang-Hui, Ma, Bing-He, Deng, Jin-Jun, Yuan, Wei-Zheng, Liu, Kang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111537/
https://www.ncbi.nlm.nih.gov/pubmed/30111724
http://dx.doi.org/10.3390/s18082682
_version_ 1783350672511467520
author Ding, Guang-Hui
Ma, Bing-He
Deng, Jin-Jun
Yuan, Wei-Zheng
Liu, Kang
author_facet Ding, Guang-Hui
Ma, Bing-He
Deng, Jin-Jun
Yuan, Wei-Zheng
Liu, Kang
author_sort Ding, Guang-Hui
collection PubMed
description A micro-floating element wall shear stress sensor with backside connections has been developed for accurate measurements of wall shear stress under the turbulent boundary layer. The micro-sensor was designed and fabricated on a 10.16 cm SOI (Silicon on Insulator) wafer by MEMS (Micro-Electro-Mechanical System) processing technology. Then, it was calibrated by a wind tunnel setup over a range of 0 Pa to 65 Pa. The measurements of wall shear stress on a smooth plate were carried out in a 0.6 m × 0.6 m transonic wind tunnel. Flow speed ranges from 0.4 Ma to 0.8 Ma, with a corresponding Reynold number of 1.05 × 10(6)~1.55 × 10(6) at the micro-sensor location. Wall shear stress measured by the micro-sensor has a range of about 34 Pa to 93 Pa, which is consistent with theoretical values. For comparisons, a Preston tube was also used to measure wall shear stress at the same time. The results show that wall shear stress obtained by three methods (the micro-sensor, a Preston tube, and theoretical results) are well agreed with each other.
format Online
Article
Text
id pubmed-6111537
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61115372018-08-30 Accurate Measurements of Wall Shear Stress on a Plate with Elliptic Leading Edge Ding, Guang-Hui Ma, Bing-He Deng, Jin-Jun Yuan, Wei-Zheng Liu, Kang Sensors (Basel) Article A micro-floating element wall shear stress sensor with backside connections has been developed for accurate measurements of wall shear stress under the turbulent boundary layer. The micro-sensor was designed and fabricated on a 10.16 cm SOI (Silicon on Insulator) wafer by MEMS (Micro-Electro-Mechanical System) processing technology. Then, it was calibrated by a wind tunnel setup over a range of 0 Pa to 65 Pa. The measurements of wall shear stress on a smooth plate were carried out in a 0.6 m × 0.6 m transonic wind tunnel. Flow speed ranges from 0.4 Ma to 0.8 Ma, with a corresponding Reynold number of 1.05 × 10(6)~1.55 × 10(6) at the micro-sensor location. Wall shear stress measured by the micro-sensor has a range of about 34 Pa to 93 Pa, which is consistent with theoretical values. For comparisons, a Preston tube was also used to measure wall shear stress at the same time. The results show that wall shear stress obtained by three methods (the micro-sensor, a Preston tube, and theoretical results) are well agreed with each other. MDPI 2018-08-15 /pmc/articles/PMC6111537/ /pubmed/30111724 http://dx.doi.org/10.3390/s18082682 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ding, Guang-Hui
Ma, Bing-He
Deng, Jin-Jun
Yuan, Wei-Zheng
Liu, Kang
Accurate Measurements of Wall Shear Stress on a Plate with Elliptic Leading Edge
title Accurate Measurements of Wall Shear Stress on a Plate with Elliptic Leading Edge
title_full Accurate Measurements of Wall Shear Stress on a Plate with Elliptic Leading Edge
title_fullStr Accurate Measurements of Wall Shear Stress on a Plate with Elliptic Leading Edge
title_full_unstemmed Accurate Measurements of Wall Shear Stress on a Plate with Elliptic Leading Edge
title_short Accurate Measurements of Wall Shear Stress on a Plate with Elliptic Leading Edge
title_sort accurate measurements of wall shear stress on a plate with elliptic leading edge
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111537/
https://www.ncbi.nlm.nih.gov/pubmed/30111724
http://dx.doi.org/10.3390/s18082682
work_keys_str_mv AT dingguanghui accuratemeasurementsofwallshearstressonaplatewithellipticleadingedge
AT mabinghe accuratemeasurementsofwallshearstressonaplatewithellipticleadingedge
AT dengjinjun accuratemeasurementsofwallshearstressonaplatewithellipticleadingedge
AT yuanweizheng accuratemeasurementsofwallshearstressonaplatewithellipticleadingedge
AT liukang accuratemeasurementsofwallshearstressonaplatewithellipticleadingedge