Total Knee Arthroplasty Wrong Side Implant

We report a unique wrong implant error during bilateral total knee replacement procedure in 72-year-old woman with bilateral knee osteoarthritis that failed conservative treatment. Patient has severe bilateral knee pain. Examination showed full range of motion. X-ray showed severe bilateral tricompa...

Descripción completa

Detalles Bibliográficos
Autores principales: Alanazi, Hassan, Alahmari, Mousa, Hashem, Musaab Abdullah, Alqahtani, Muath, Alanazi, Abdulaziz, Alenazi, Bashir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical Publishers 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6160294/
https://www.ncbi.nlm.nih.gov/pubmed/30271877