Cargando…
A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators
Microelectromechanical systems (MEMS) resonators require fast, accurate, and cost-effective testing for mass production. Among the different test methods, frequency domain analysis is one of the easiest and fastest. This paper presents the measurement uncertainties in electrostatically actuated MEMS...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187468/ https://www.ncbi.nlm.nih.gov/pubmed/30424106 http://dx.doi.org/10.3390/mi9040173 |
_version_ | 1783363026492063744 |
---|---|
author | Iqbal, Faisal Lee, Byeungleul |
author_facet | Iqbal, Faisal Lee, Byeungleul |
author_sort | Iqbal, Faisal |
collection | PubMed |
description | Microelectromechanical systems (MEMS) resonators require fast, accurate, and cost-effective testing for mass production. Among the different test methods, frequency domain analysis is one of the easiest and fastest. This paper presents the measurement uncertainties in electrostatically actuated MEMS resonators, using frequency domain analysis. The influence of the applied driving force was studied to evaluate the measurement variations in resonant characteristics, such as the natural frequency and the quality factor of the resonator. To quantify the measurement results, measurement system analysis (MSA) was performed using the analysis of variance (ANOVA) method. The results demonstrate that the resonant frequency ([Formula: see text]) is mostly affected by systematic error. However, the quality (Q) factor strongly depends on the applied driving force. To reduce the measurement variations in Q factor, experiments were carried out to study the influence of DC and/or AC driving voltages on the resonator. The results reveal that measurement uncertainties in the quality factor were high for a small electrostatic force. |
format | Online Article Text |
id | pubmed-6187468 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-61874682018-11-01 A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators Iqbal, Faisal Lee, Byeungleul Micromachines (Basel) Article Microelectromechanical systems (MEMS) resonators require fast, accurate, and cost-effective testing for mass production. Among the different test methods, frequency domain analysis is one of the easiest and fastest. This paper presents the measurement uncertainties in electrostatically actuated MEMS resonators, using frequency domain analysis. The influence of the applied driving force was studied to evaluate the measurement variations in resonant characteristics, such as the natural frequency and the quality factor of the resonator. To quantify the measurement results, measurement system analysis (MSA) was performed using the analysis of variance (ANOVA) method. The results demonstrate that the resonant frequency ([Formula: see text]) is mostly affected by systematic error. However, the quality (Q) factor strongly depends on the applied driving force. To reduce the measurement variations in Q factor, experiments were carried out to study the influence of DC and/or AC driving voltages on the resonator. The results reveal that measurement uncertainties in the quality factor were high for a small electrostatic force. MDPI 2018-04-09 /pmc/articles/PMC6187468/ /pubmed/30424106 http://dx.doi.org/10.3390/mi9040173 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Iqbal, Faisal Lee, Byeungleul A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators |
title | A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators |
title_full | A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators |
title_fullStr | A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators |
title_full_unstemmed | A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators |
title_short | A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators |
title_sort | study on measurement variations in resonant characteristics of electrostatically actuated mems resonators |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187468/ https://www.ncbi.nlm.nih.gov/pubmed/30424106 http://dx.doi.org/10.3390/mi9040173 |
work_keys_str_mv | AT iqbalfaisal astudyonmeasurementvariationsinresonantcharacteristicsofelectrostaticallyactuatedmemsresonators AT leebyeungleul astudyonmeasurementvariationsinresonantcharacteristicsofelectrostaticallyactuatedmemsresonators AT iqbalfaisal studyonmeasurementvariationsinresonantcharacteristicsofelectrostaticallyactuatedmemsresonators AT leebyeungleul studyonmeasurementvariationsinresonantcharacteristicsofelectrostaticallyactuatedmemsresonators |