A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators

Microelectromechanical systems (MEMS) resonators require fast, accurate, and cost-effective testing for mass production. Among the different test methods, frequency domain analysis is one of the easiest and fastest. This paper presents the measurement uncertainties in electrostatically actuated MEMS...

Descripción completa

Detalles Bibliográficos
Autores principales: Iqbal, Faisal, Lee, Byeungleul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187468/
https://www.ncbi.nlm.nih.gov/pubmed/30424106
http://dx.doi.org/10.3390/mi9040173
_version_ 1783363026492063744
author Iqbal, Faisal
Lee, Byeungleul
author_facet Iqbal, Faisal
Lee, Byeungleul
author_sort Iqbal, Faisal
collection PubMed
description Microelectromechanical systems (MEMS) resonators require fast, accurate, and cost-effective testing for mass production. Among the different test methods, frequency domain analysis is one of the easiest and fastest. This paper presents the measurement uncertainties in electrostatically actuated MEMS resonators, using frequency domain analysis. The influence of the applied driving force was studied to evaluate the measurement variations in resonant characteristics, such as the natural frequency and the quality factor of the resonator. To quantify the measurement results, measurement system analysis (MSA) was performed using the analysis of variance (ANOVA) method. The results demonstrate that the resonant frequency ([Formula: see text]) is mostly affected by systematic error. However, the quality (Q) factor strongly depends on the applied driving force. To reduce the measurement variations in Q factor, experiments were carried out to study the influence of DC and/or AC driving voltages on the resonator. The results reveal that measurement uncertainties in the quality factor were high for a small electrostatic force.
format Online
Article
Text
id pubmed-6187468
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-61874682018-11-01 A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators Iqbal, Faisal Lee, Byeungleul Micromachines (Basel) Article Microelectromechanical systems (MEMS) resonators require fast, accurate, and cost-effective testing for mass production. Among the different test methods, frequency domain analysis is one of the easiest and fastest. This paper presents the measurement uncertainties in electrostatically actuated MEMS resonators, using frequency domain analysis. The influence of the applied driving force was studied to evaluate the measurement variations in resonant characteristics, such as the natural frequency and the quality factor of the resonator. To quantify the measurement results, measurement system analysis (MSA) was performed using the analysis of variance (ANOVA) method. The results demonstrate that the resonant frequency ([Formula: see text]) is mostly affected by systematic error. However, the quality (Q) factor strongly depends on the applied driving force. To reduce the measurement variations in Q factor, experiments were carried out to study the influence of DC and/or AC driving voltages on the resonator. The results reveal that measurement uncertainties in the quality factor were high for a small electrostatic force. MDPI 2018-04-09 /pmc/articles/PMC6187468/ /pubmed/30424106 http://dx.doi.org/10.3390/mi9040173 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Iqbal, Faisal
Lee, Byeungleul
A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators
title A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators
title_full A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators
title_fullStr A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators
title_full_unstemmed A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators
title_short A Study on Measurement Variations in Resonant Characteristics of Electrostatically Actuated MEMS Resonators
title_sort study on measurement variations in resonant characteristics of electrostatically actuated mems resonators
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187468/
https://www.ncbi.nlm.nih.gov/pubmed/30424106
http://dx.doi.org/10.3390/mi9040173
work_keys_str_mv AT iqbalfaisal astudyonmeasurementvariationsinresonantcharacteristicsofelectrostaticallyactuatedmemsresonators
AT leebyeungleul astudyonmeasurementvariationsinresonantcharacteristicsofelectrostaticallyactuatedmemsresonators
AT iqbalfaisal studyonmeasurementvariationsinresonantcharacteristicsofelectrostaticallyactuatedmemsresonators
AT leebyeungleul studyonmeasurementvariationsinresonantcharacteristicsofelectrostaticallyactuatedmemsresonators