Detection of Particulate Matter of Size 2.5 μm with a Surface-Acoustic-Wave Sensor Combined with a Cyclone Separator

A device to monitor particulate matter of size 2.5 μm (PM2.5) that has been designed and developed includes a surface-acoustic-wave sensor operating in a shear horizontal mode (SH-SAW) combined with a cyclone separator. In our tests, aerosols generated as incense smoke were first separated and sampl...

Descripción completa

Detalles Bibliográficos
Autores principales: Kuo, Fung-Yu, Lin, Ying-Chen, Ke, Ling-Yi, Tsai, Chuen-Jinn, Yao, Da-Jeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6187824/
https://www.ncbi.nlm.nih.gov/pubmed/30424331