Dose comparison between prescription methods according to anatomical variations in intracavitary brachytherapy for cervical cancer

PURPOSE: We compared how doses delivered via two-dimensional (2D) intracavitary brachytherapy (ICBT) and three-dimensional (3D) ICBT varied anatomically. MATERIALS AND METHODS: A total of 50 patients who received 30 Gy of 3D ICBT after external radiotherapy (RT) were enrolled. We compared the doses...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Euncheol, Kim, Jae Ho, Kim, Ok Bae, Byun, Sang Jun, Kim, Jin Hee, Oh, Young Kee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Radiation Oncology 2018