Cargando…

On the Traceability of Commercial Saffron Samples Using (1)H-NMR and FT-IR Metabolomics

In previous works on authentic samples of saffron of known history (harvest and processing year, storage conditions, and length of time) some biomarkers were proposed using both FT-IR and NMR metabolomics regarding the shelf life of the product. This work addresses the difficulties to trace back the...

Descripción completa

Detalles Bibliográficos
Autores principales: Consonni, Roberto, Ordoudi, Stella A., Cagliani, Laura R., Tsiangali, Maria, Tsimidou, Maria Z.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6274441/
https://www.ncbi.nlm.nih.gov/pubmed/26938515
http://dx.doi.org/10.3390/molecules21030286
_version_ 1783377619050299392
author Consonni, Roberto
Ordoudi, Stella A.
Cagliani, Laura R.
Tsiangali, Maria
Tsimidou, Maria Z.
author_facet Consonni, Roberto
Ordoudi, Stella A.
Cagliani, Laura R.
Tsiangali, Maria
Tsimidou, Maria Z.
author_sort Consonni, Roberto
collection PubMed
description In previous works on authentic samples of saffron of known history (harvest and processing year, storage conditions, and length of time) some biomarkers were proposed using both FT-IR and NMR metabolomics regarding the shelf life of the product. This work addresses the difficulties to trace back the “age” of commercial saffron samples of unknown history, sets a limit value above which these products can be considered substandard, and offers a useful tool to combat saffron mislabeling and fraud with low-quality saffron material. Investigations of authentic and commercial saffron samples of different origin and harvest year, which had been stored under controlled conditions for different lengths of time, allowed a clear-cut clustering of samples in two groups according to the storage period irrespectively of the provenience. In this respect, the four-year cut off point proposed in our previous work assisted to trace back the “age” of unknown samples and to check for possible mislabeling practices.
format Online
Article
Text
id pubmed-6274441
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62744412018-12-28 On the Traceability of Commercial Saffron Samples Using (1)H-NMR and FT-IR Metabolomics Consonni, Roberto Ordoudi, Stella A. Cagliani, Laura R. Tsiangali, Maria Tsimidou, Maria Z. Molecules Communication In previous works on authentic samples of saffron of known history (harvest and processing year, storage conditions, and length of time) some biomarkers were proposed using both FT-IR and NMR metabolomics regarding the shelf life of the product. This work addresses the difficulties to trace back the “age” of commercial saffron samples of unknown history, sets a limit value above which these products can be considered substandard, and offers a useful tool to combat saffron mislabeling and fraud with low-quality saffron material. Investigations of authentic and commercial saffron samples of different origin and harvest year, which had been stored under controlled conditions for different lengths of time, allowed a clear-cut clustering of samples in two groups according to the storage period irrespectively of the provenience. In this respect, the four-year cut off point proposed in our previous work assisted to trace back the “age” of unknown samples and to check for possible mislabeling practices. MDPI 2016-02-29 /pmc/articles/PMC6274441/ /pubmed/26938515 http://dx.doi.org/10.3390/molecules21030286 Text en © 2016 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Consonni, Roberto
Ordoudi, Stella A.
Cagliani, Laura R.
Tsiangali, Maria
Tsimidou, Maria Z.
On the Traceability of Commercial Saffron Samples Using (1)H-NMR and FT-IR Metabolomics
title On the Traceability of Commercial Saffron Samples Using (1)H-NMR and FT-IR Metabolomics
title_full On the Traceability of Commercial Saffron Samples Using (1)H-NMR and FT-IR Metabolomics
title_fullStr On the Traceability of Commercial Saffron Samples Using (1)H-NMR and FT-IR Metabolomics
title_full_unstemmed On the Traceability of Commercial Saffron Samples Using (1)H-NMR and FT-IR Metabolomics
title_short On the Traceability of Commercial Saffron Samples Using (1)H-NMR and FT-IR Metabolomics
title_sort on the traceability of commercial saffron samples using (1)h-nmr and ft-ir metabolomics
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6274441/
https://www.ncbi.nlm.nih.gov/pubmed/26938515
http://dx.doi.org/10.3390/molecules21030286
work_keys_str_mv AT consonniroberto onthetraceabilityofcommercialsaffronsamplesusing1hnmrandftirmetabolomics
AT ordoudistellaa onthetraceabilityofcommercialsaffronsamplesusing1hnmrandftirmetabolomics
AT caglianilaurar onthetraceabilityofcommercialsaffronsamplesusing1hnmrandftirmetabolomics
AT tsiangalimaria onthetraceabilityofcommercialsaffronsamplesusing1hnmrandftirmetabolomics
AT tsimidoumariaz onthetraceabilityofcommercialsaffronsamplesusing1hnmrandftirmetabolomics