Cargando…

A broadly applicable COI primer pair and an efficient single‐tube amplicon library preparation protocol for metabarcoding

The nucleotide variation in the cytochrome c oxidase subunit I (COI) gene makes it ideal for assigning sequences to species. However, this variability also makes it difficult to design truly universal primers. Here, we present the forward primer “Sauron‐S878,” specifically designed to facilitate lib...

Descripción completa

Detalles Bibliográficos
Autores principales: Rennstam Rubbmark, Oskar, Sint, Daniela, Horngacher, Nina, Traugott, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308894/
https://www.ncbi.nlm.nih.gov/pubmed/30619549
http://dx.doi.org/10.1002/ece3.4520
_version_ 1783383295969460224
author Rennstam Rubbmark, Oskar
Sint, Daniela
Horngacher, Nina
Traugott, Michael
author_facet Rennstam Rubbmark, Oskar
Sint, Daniela
Horngacher, Nina
Traugott, Michael
author_sort Rennstam Rubbmark, Oskar
collection PubMed
description The nucleotide variation in the cytochrome c oxidase subunit I (COI) gene makes it ideal for assigning sequences to species. However, this variability also makes it difficult to design truly universal primers. Here, we present the forward primer “Sauron‐S878,” specifically designed to facilitate library preparation for metabarcoding. This primer is modified to improve the coverage of terrestrial species compared to the primer mCOIintF, optimized for aquatic systems, which raised the in silico coverage from 74.4% to 98.3% of available NCBI sequences (perfect match in 3′ region, up to three mismatches in remaining primer). When paired with the reverse primer “jgHCO2198” (fragment length ~313 bp), these primers amplified 98.4% of 255 tested DNA extracts from various taxa, which are better than many other common COI barcoding primers. Furthermore, a single‐tube protocol was developed, wherein these primers amplify the target gene, and attach MIDs and Illumina sequencing adapters in one reaction. This eliminates the need for re‐amplification or enzymatic ligation during library preparation while keeping the flexibility to modularly combine primers and MIDs. Using the single‐tube approach, three replicates of three mock samples were sequenced on a MiSeq platform with no adverse effects compared to commercial Nextera indexing kits. From this run, 75% of all included taxa could be recovered, with no considerable bias among taxonomic groups. Despite the fact that 98.4% of the extracts were confirmed to amplify in vitro, this number was lower than expected. A reason for this discrepancy was a clear link between the relative concentration of a specific DNA type in the template and the number of returned reads for this DNA. We would argue that such a bias may be especially problematic in metabarcoding where samples usually contain trace DNA in unknown amounts. However, how this affects the completeness of metabarcoding results has yet been poorly investigated.
format Online
Article
Text
id pubmed-6308894
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-63088942019-01-07 A broadly applicable COI primer pair and an efficient single‐tube amplicon library preparation protocol for metabarcoding Rennstam Rubbmark, Oskar Sint, Daniela Horngacher, Nina Traugott, Michael Ecol Evol Original Research The nucleotide variation in the cytochrome c oxidase subunit I (COI) gene makes it ideal for assigning sequences to species. However, this variability also makes it difficult to design truly universal primers. Here, we present the forward primer “Sauron‐S878,” specifically designed to facilitate library preparation for metabarcoding. This primer is modified to improve the coverage of terrestrial species compared to the primer mCOIintF, optimized for aquatic systems, which raised the in silico coverage from 74.4% to 98.3% of available NCBI sequences (perfect match in 3′ region, up to three mismatches in remaining primer). When paired with the reverse primer “jgHCO2198” (fragment length ~313 bp), these primers amplified 98.4% of 255 tested DNA extracts from various taxa, which are better than many other common COI barcoding primers. Furthermore, a single‐tube protocol was developed, wherein these primers amplify the target gene, and attach MIDs and Illumina sequencing adapters in one reaction. This eliminates the need for re‐amplification or enzymatic ligation during library preparation while keeping the flexibility to modularly combine primers and MIDs. Using the single‐tube approach, three replicates of three mock samples were sequenced on a MiSeq platform with no adverse effects compared to commercial Nextera indexing kits. From this run, 75% of all included taxa could be recovered, with no considerable bias among taxonomic groups. Despite the fact that 98.4% of the extracts were confirmed to amplify in vitro, this number was lower than expected. A reason for this discrepancy was a clear link between the relative concentration of a specific DNA type in the template and the number of returned reads for this DNA. We would argue that such a bias may be especially problematic in metabarcoding where samples usually contain trace DNA in unknown amounts. However, how this affects the completeness of metabarcoding results has yet been poorly investigated. John Wiley and Sons Inc. 2018-12-11 /pmc/articles/PMC6308894/ /pubmed/30619549 http://dx.doi.org/10.1002/ece3.4520 Text en © 2018 The Authors. Ecology and Evolution published by John Wiley & Sons Ltd. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Rennstam Rubbmark, Oskar
Sint, Daniela
Horngacher, Nina
Traugott, Michael
A broadly applicable COI primer pair and an efficient single‐tube amplicon library preparation protocol for metabarcoding
title A broadly applicable COI primer pair and an efficient single‐tube amplicon library preparation protocol for metabarcoding
title_full A broadly applicable COI primer pair and an efficient single‐tube amplicon library preparation protocol for metabarcoding
title_fullStr A broadly applicable COI primer pair and an efficient single‐tube amplicon library preparation protocol for metabarcoding
title_full_unstemmed A broadly applicable COI primer pair and an efficient single‐tube amplicon library preparation protocol for metabarcoding
title_short A broadly applicable COI primer pair and an efficient single‐tube amplicon library preparation protocol for metabarcoding
title_sort broadly applicable coi primer pair and an efficient single‐tube amplicon library preparation protocol for metabarcoding
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308894/
https://www.ncbi.nlm.nih.gov/pubmed/30619549
http://dx.doi.org/10.1002/ece3.4520
work_keys_str_mv AT rennstamrubbmarkoskar abroadlyapplicablecoiprimerpairandanefficientsingletubeampliconlibrarypreparationprotocolformetabarcoding
AT sintdaniela abroadlyapplicablecoiprimerpairandanefficientsingletubeampliconlibrarypreparationprotocolformetabarcoding
AT horngachernina abroadlyapplicablecoiprimerpairandanefficientsingletubeampliconlibrarypreparationprotocolformetabarcoding
AT traugottmichael abroadlyapplicablecoiprimerpairandanefficientsingletubeampliconlibrarypreparationprotocolformetabarcoding
AT rennstamrubbmarkoskar broadlyapplicablecoiprimerpairandanefficientsingletubeampliconlibrarypreparationprotocolformetabarcoding
AT sintdaniela broadlyapplicablecoiprimerpairandanefficientsingletubeampliconlibrarypreparationprotocolformetabarcoding
AT horngachernina broadlyapplicablecoiprimerpairandanefficientsingletubeampliconlibrarypreparationprotocolformetabarcoding
AT traugottmichael broadlyapplicablecoiprimerpairandanefficientsingletubeampliconlibrarypreparationprotocolformetabarcoding