Cargando…

Fenestrated aortic endograft branching with Gore VBX poses failure risk from delayed-onset branch kinking

The Gore VBX stent graft (Gore Medical, Flagstaff, Ariz) provides a new option for branching of fenestrated aortic endografts. However, its modular stent structure has raised concerns about potential kinking at the interspace between stent rings if lateralizing force exists between the fenestration...

Descripción completa

Detalles Bibliográficos
Autores principales: Yi, Jeniann A., Kuwayama, David P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6313828/
https://www.ncbi.nlm.nih.gov/pubmed/30619985
http://dx.doi.org/10.1016/j.jvscit.2018.08.011