Automated expiratory ventilation assistance through a small endotracheal tube can improve venous return and cardiac output
BACKGROUND: Positive pressure ventilation can decrease venous return and cardiac output. It is not known if expiratory ventilation assistance (EVA) through a small endotracheal tube can improve venous return and cardiac output. RESULTS: In a porcine model, switching from conventional positive pressu...