Assessment of awake i-gel™ insertion for fiberoptic-guided intubation in patients with predicted difficult airway: A prospective, observational study

BACKGROUND AND AIMS: Orotracheal intubation (OTI) with fiberoptic bronchoscope (FOB) in spontaneous ventilation is one of the main techniques for patients with predicted difficult airway. Latest generation supraglottic airway devices have been designed to allow OTI through them. We assessed the safe...