ACCURACY OF PEDICLE SCREW INSERTION: A COMPARISON BETWEEN FLUOROSCOPIC GUIDANCE AND NAVIGATION TECHNIQUES

OBJECTIVES: To compare the accuracy of insertion of pedicle screws into the thoracic spine using fluoroscopic guidance or computer-assisted navigation techniques. METHODS: Eight cadaveric thoracic spines were divided into two groups: the fluoroscopy group, in which pedicle screws were inserted with...

Descripción completa

Detalles Bibliográficos
Autores principales: Bilhar, Romero Pinto de Oliveira, de Lima, Diego Ariel, Leite, José Alberto Dias, Porto, Maximiliano Aguiar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: ATHA EDITORA 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6362689/
https://www.ncbi.nlm.nih.gov/pubmed/30774514
http://dx.doi.org/10.1590/1413-785220182606180635