Cargando…

Model predictive control of a robotically actuated delivery sheath for beating heart compensation

Minimally invasive surgery (MIS) during cardiovascular interventions reduces trauma and enables the treatment of high-risk patients who were initially denied surgery. However, restricted access, reduced visibility and control of the instrument at the treatment locations limits the performance and ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Vrooijink, Gustaaf J, Denasi, Alper, Grandjean, Jan G, Misra, Sarthak
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6368306/
https://www.ncbi.nlm.nih.gov/pubmed/30814767
http://dx.doi.org/10.1177/0278364917691113
_version_ 1783393965124354048
author Vrooijink, Gustaaf J
Denasi, Alper
Grandjean, Jan G
Misra, Sarthak
author_facet Vrooijink, Gustaaf J
Denasi, Alper
Grandjean, Jan G
Misra, Sarthak
author_sort Vrooijink, Gustaaf J
collection PubMed
description Minimally invasive surgery (MIS) during cardiovascular interventions reduces trauma and enables the treatment of high-risk patients who were initially denied surgery. However, restricted access, reduced visibility and control of the instrument at the treatment locations limits the performance and capabilities of such interventions during MIS. Therefore, the demand for technology such as steerable sheaths or catheters that assist the clinician during the procedure is increasing. In this study, we present and evaluate a robotically actuated delivery sheath (RADS) capable of autonomously and accurately compensating for beating heart motions by using a model-predictive control (MPC) strategy. We develop kinematic models and present online ultrasound segmentation of the RADS that are integrated with the MPC strategy. As a case study, we use pre-operative ultrasound images from a patient to extract motion profiles of the aortic heart valve (AHV). This allows the MPC strategy to anticipate for AHV motions. Further, mechanical hysteresis in the steering mechanism is compensated for in order to improve tip positioning accuracy. The novel integrated system is capable of controlling the articulating tip of the RADS to assist the clinician during cardiovascular surgery. Experiments demonstrate that the RADS follows the AHV motion with a mean positioning error of 1.68 mm. The presented modelling, imaging and control framework could be adapted and applied to a range of continuum-style robots and catheters for various cardiovascular interventions.
format Online
Article
Text
id pubmed-6368306
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-63683062019-02-25 Model predictive control of a robotically actuated delivery sheath for beating heart compensation Vrooijink, Gustaaf J Denasi, Alper Grandjean, Jan G Misra, Sarthak Int J Rob Res Article Minimally invasive surgery (MIS) during cardiovascular interventions reduces trauma and enables the treatment of high-risk patients who were initially denied surgery. However, restricted access, reduced visibility and control of the instrument at the treatment locations limits the performance and capabilities of such interventions during MIS. Therefore, the demand for technology such as steerable sheaths or catheters that assist the clinician during the procedure is increasing. In this study, we present and evaluate a robotically actuated delivery sheath (RADS) capable of autonomously and accurately compensating for beating heart motions by using a model-predictive control (MPC) strategy. We develop kinematic models and present online ultrasound segmentation of the RADS that are integrated with the MPC strategy. As a case study, we use pre-operative ultrasound images from a patient to extract motion profiles of the aortic heart valve (AHV). This allows the MPC strategy to anticipate for AHV motions. Further, mechanical hysteresis in the steering mechanism is compensated for in order to improve tip positioning accuracy. The novel integrated system is capable of controlling the articulating tip of the RADS to assist the clinician during cardiovascular surgery. Experiments demonstrate that the RADS follows the AHV motion with a mean positioning error of 1.68 mm. The presented modelling, imaging and control framework could be adapted and applied to a range of continuum-style robots and catheters for various cardiovascular interventions. SAGE Publications 2017-02-01 2017-02 /pmc/articles/PMC6368306/ /pubmed/30814767 http://dx.doi.org/10.1177/0278364917691113 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Vrooijink, Gustaaf J
Denasi, Alper
Grandjean, Jan G
Misra, Sarthak
Model predictive control of a robotically actuated delivery sheath for beating heart compensation
title Model predictive control of a robotically actuated delivery sheath for beating heart compensation
title_full Model predictive control of a robotically actuated delivery sheath for beating heart compensation
title_fullStr Model predictive control of a robotically actuated delivery sheath for beating heart compensation
title_full_unstemmed Model predictive control of a robotically actuated delivery sheath for beating heart compensation
title_short Model predictive control of a robotically actuated delivery sheath for beating heart compensation
title_sort model predictive control of a robotically actuated delivery sheath for beating heart compensation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6368306/
https://www.ncbi.nlm.nih.gov/pubmed/30814767
http://dx.doi.org/10.1177/0278364917691113
work_keys_str_mv AT vrooijinkgustaafj modelpredictivecontrolofaroboticallyactuateddeliverysheathforbeatingheartcompensation
AT denasialper modelpredictivecontrolofaroboticallyactuateddeliverysheathforbeatingheartcompensation
AT grandjeanjang modelpredictivecontrolofaroboticallyactuateddeliverysheathforbeatingheartcompensation
AT misrasarthak modelpredictivecontrolofaroboticallyactuateddeliverysheathforbeatingheartcompensation