One-year outcomes following implantation of second-generation trabecular micro-bypass stents in conjunction with cataract surgery for various types of glaucoma or ocular hypertension: multicenter, multi-surgeon study

PURPOSE: To assess the utility and safety of implanting two second-generation trabecular micro-bypass stents following cataract surgery in eyes with mild to advanced glaucoma or ocular hypertension (OHT). PATIENTS AND METHODS: Retrospective study of iStent(®)inject trabecular micro-bypass implantati...

Descripción completa

Detalles Bibliográficos
Autores principales: Clement, Colin I, Howes, Frank, Ioannidis, Alexandros S, Shiu, Michael, Manning, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6420788/