Large-scale microfluidic gradient arrays reveal axon guidance behaviors in hippocampal neurons
High-throughput quantitative approaches to study axon growth behaviors have remained a challenge. We have developed a 1024-chamber microfluidic gradient generator array that enables large-scale investigations of axon guidance and growth dynamics from individual primary mammalian neurons, which are e...