Subacromial bone erosion due to suture-knots in arthroscopic rotator cuff repair: A report of two cases
Knot impingement can cause shoulder-joint motion pain after rotator-cuff repair. Previous studies have revealed only subacromial effusion in magnetic resonance imaging (MRI) evaluations of knot impingement. We report two cases of patients with symptomatic knot impingement. In both patients, bursal-s...