Analysis of Mechanically Activated Ion Channels at the Cell-Substrate Interface: Combining Pillar Arrays and Whole-Cell Patch-Clamp
Ionic currents can be evoked by mechanical inputs applied directly at the cell-substrate interface. These ionic currents are mediated by mechanically activated ion channels, where the open probability increases with increasing mechanical input. In order to study mechanically activated ion channels d...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6448047/ https://www.ncbi.nlm.nih.gov/pubmed/30984749 http://dx.doi.org/10.3389/fbioe.2019.00047 |
_version_ | 1783408622424817664 |
---|---|
author | Sianati, Setareh Kurumlian, Anie Bailey, Evan Poole, Kate |
author_facet | Sianati, Setareh Kurumlian, Anie Bailey, Evan Poole, Kate |
author_sort | Sianati, Setareh |
collection | PubMed |
description | Ionic currents can be evoked by mechanical inputs applied directly at the cell-substrate interface. These ionic currents are mediated by mechanically activated ion channels, where the open probability increases with increasing mechanical input. In order to study mechanically activated ion channels directly at the interface between cells and their environment, we have developed a technique to simultaneously monitor ion channel activity whilst stimuli are applied via displacement of cell-substrate contacts. This technique utilizes whole-cell patch-clamp electrophysiology and elastomeric pillar arrays, it is quantitative and appropriate for studying channels that respond to stimuli that are propagated to an adherent cell via the physical substrate. The mammalian channels PIEZO1, PIEZO2 have been shown to be activated by substrate deflections, using this technique. In addition, TRPV4 mediated currents can be evoked by substrate deflections, in contrast to alternate stimulation methods such as membrane stretch or cellular indentation. The deflections applied at cell-substrate points mimic the magnitude of physical stimuli that impact cells in situ. |
format | Online Article Text |
id | pubmed-6448047 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-64480472019-04-12 Analysis of Mechanically Activated Ion Channels at the Cell-Substrate Interface: Combining Pillar Arrays and Whole-Cell Patch-Clamp Sianati, Setareh Kurumlian, Anie Bailey, Evan Poole, Kate Front Bioeng Biotechnol Bioengineering and Biotechnology Ionic currents can be evoked by mechanical inputs applied directly at the cell-substrate interface. These ionic currents are mediated by mechanically activated ion channels, where the open probability increases with increasing mechanical input. In order to study mechanically activated ion channels directly at the interface between cells and their environment, we have developed a technique to simultaneously monitor ion channel activity whilst stimuli are applied via displacement of cell-substrate contacts. This technique utilizes whole-cell patch-clamp electrophysiology and elastomeric pillar arrays, it is quantitative and appropriate for studying channels that respond to stimuli that are propagated to an adherent cell via the physical substrate. The mammalian channels PIEZO1, PIEZO2 have been shown to be activated by substrate deflections, using this technique. In addition, TRPV4 mediated currents can be evoked by substrate deflections, in contrast to alternate stimulation methods such as membrane stretch or cellular indentation. The deflections applied at cell-substrate points mimic the magnitude of physical stimuli that impact cells in situ. Frontiers Media S.A. 2019-03-22 /pmc/articles/PMC6448047/ /pubmed/30984749 http://dx.doi.org/10.3389/fbioe.2019.00047 Text en Copyright © 2019 Sianati, Kurumlian, Bailey and Poole. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Sianati, Setareh Kurumlian, Anie Bailey, Evan Poole, Kate Analysis of Mechanically Activated Ion Channels at the Cell-Substrate Interface: Combining Pillar Arrays and Whole-Cell Patch-Clamp |
title | Analysis of Mechanically Activated Ion Channels at the Cell-Substrate Interface: Combining Pillar Arrays and Whole-Cell Patch-Clamp |
title_full | Analysis of Mechanically Activated Ion Channels at the Cell-Substrate Interface: Combining Pillar Arrays and Whole-Cell Patch-Clamp |
title_fullStr | Analysis of Mechanically Activated Ion Channels at the Cell-Substrate Interface: Combining Pillar Arrays and Whole-Cell Patch-Clamp |
title_full_unstemmed | Analysis of Mechanically Activated Ion Channels at the Cell-Substrate Interface: Combining Pillar Arrays and Whole-Cell Patch-Clamp |
title_short | Analysis of Mechanically Activated Ion Channels at the Cell-Substrate Interface: Combining Pillar Arrays and Whole-Cell Patch-Clamp |
title_sort | analysis of mechanically activated ion channels at the cell-substrate interface: combining pillar arrays and whole-cell patch-clamp |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6448047/ https://www.ncbi.nlm.nih.gov/pubmed/30984749 http://dx.doi.org/10.3389/fbioe.2019.00047 |
work_keys_str_mv | AT sianatisetareh analysisofmechanicallyactivatedionchannelsatthecellsubstrateinterfacecombiningpillararraysandwholecellpatchclamp AT kurumliananie analysisofmechanicallyactivatedionchannelsatthecellsubstrateinterfacecombiningpillararraysandwholecellpatchclamp AT baileyevan analysisofmechanicallyactivatedionchannelsatthecellsubstrateinterfacecombiningpillararraysandwholecellpatchclamp AT poolekate analysisofmechanicallyactivatedionchannelsatthecellsubstrateinterfacecombiningpillararraysandwholecellpatchclamp |