Comparison of Titanium and Bioresorbable Plates in “A” Shape Plate Properties—Finite Element Analysis
(1) Background: The main disadvantage of rigid fracture fixation is remain material after healing period. Implementation of resorbable plates prevents issues resulting from left plates. The aim of this study is to compare the usage of bioresorbable and titanium “A” shape condyle plate in condylar fr...