Cargando…

A safe percutaneous technique for the reduction of irreducible femoral neck fractures using ultrasound localization of the femoral vascular and nervous structures at the hip

We present a safe percutaneous technique for the placement of Kirschner wires into the femoral head to assist in the reduction of irreducible femoral neck fractures using ultrasound to identify the vascular and nervous structures about the hip. From January 2011 to June 2014, a total of 36 patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Shuisheng, Xu, Xinzhong, Pandey, Nitesh Raj, Zhao, Yao, Jing, Juehua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6485823/
https://www.ncbi.nlm.nih.gov/pubmed/30985696
http://dx.doi.org/10.1097/MD.0000000000015163