Nonlinear Behavior of Electrostatically Actuated Microbeams with Coupled Longitudinal–Transversal Vibration

Microelectromechanical switch has become an essential component in a wide variety of applications, ranging from biomechanics and aerospace engineering to consumer electronics. Electrostatically actuated microbeams and microplates are chief parts of many MEMS instruments. In this study, the nonlinear...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Chicheng, Cao, Limin, Li, Lei, Shao, Mingyu, Jing, Dong, Guo, Zonghe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6562969/
https://www.ncbi.nlm.nih.gov/pubmed/31083425
http://dx.doi.org/10.3390/mi10050315
_version_ 1783426444906463232
author Ma, Chicheng
Cao, Limin
Li, Lei
Shao, Mingyu
Jing, Dong
Guo, Zonghe
author_facet Ma, Chicheng
Cao, Limin
Li, Lei
Shao, Mingyu
Jing, Dong
Guo, Zonghe
author_sort Ma, Chicheng
collection PubMed
description Microelectromechanical switch has become an essential component in a wide variety of applications, ranging from biomechanics and aerospace engineering to consumer electronics. Electrostatically actuated microbeams and microplates are chief parts of many MEMS instruments. In this study, the nonlinear characteristics of coupled longitudinal–transversal vibration are analyzed, while an electrostatically actuated microbeam is designed considering that the frequency ratio is two to one between the first longitudinal vibration and transversal vibration. The nonlinear governing equations are truncated into a set of coupled ordinary differential equations by the Galerkin method. Then the equations are solved using the multiple-scales method and the nonlinear dynamics of the internal resonance is investigated. The influence of bias voltage, longitudinal excitation and frequency detuning parameters are mainly analyzed. Results show that using the pseudo-arclength continuation method, the nonlinear amplitude–response curves can be plotted continuously. The saturation and jump phenomena are greatly affected by the bias voltage and the detuning frequency. Beyond the critical excitation amplitude, the response energy will transfer from the longitudinal motion to the transversal motion, even the excitation is employed on the longitudinal direction. The large-amplitude jump of the low-order vibration mode can be used to detect the variation of the conditions or parameters, which shows great potential in improving precision of MEMS switches.
format Online
Article
Text
id pubmed-6562969
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65629692019-06-17 Nonlinear Behavior of Electrostatically Actuated Microbeams with Coupled Longitudinal–Transversal Vibration Ma, Chicheng Cao, Limin Li, Lei Shao, Mingyu Jing, Dong Guo, Zonghe Micromachines (Basel) Article Microelectromechanical switch has become an essential component in a wide variety of applications, ranging from biomechanics and aerospace engineering to consumer electronics. Electrostatically actuated microbeams and microplates are chief parts of many MEMS instruments. In this study, the nonlinear characteristics of coupled longitudinal–transversal vibration are analyzed, while an electrostatically actuated microbeam is designed considering that the frequency ratio is two to one between the first longitudinal vibration and transversal vibration. The nonlinear governing equations are truncated into a set of coupled ordinary differential equations by the Galerkin method. Then the equations are solved using the multiple-scales method and the nonlinear dynamics of the internal resonance is investigated. The influence of bias voltage, longitudinal excitation and frequency detuning parameters are mainly analyzed. Results show that using the pseudo-arclength continuation method, the nonlinear amplitude–response curves can be plotted continuously. The saturation and jump phenomena are greatly affected by the bias voltage and the detuning frequency. Beyond the critical excitation amplitude, the response energy will transfer from the longitudinal motion to the transversal motion, even the excitation is employed on the longitudinal direction. The large-amplitude jump of the low-order vibration mode can be used to detect the variation of the conditions or parameters, which shows great potential in improving precision of MEMS switches. MDPI 2019-05-10 /pmc/articles/PMC6562969/ /pubmed/31083425 http://dx.doi.org/10.3390/mi10050315 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ma, Chicheng
Cao, Limin
Li, Lei
Shao, Mingyu
Jing, Dong
Guo, Zonghe
Nonlinear Behavior of Electrostatically Actuated Microbeams with Coupled Longitudinal–Transversal Vibration
title Nonlinear Behavior of Electrostatically Actuated Microbeams with Coupled Longitudinal–Transversal Vibration
title_full Nonlinear Behavior of Electrostatically Actuated Microbeams with Coupled Longitudinal–Transversal Vibration
title_fullStr Nonlinear Behavior of Electrostatically Actuated Microbeams with Coupled Longitudinal–Transversal Vibration
title_full_unstemmed Nonlinear Behavior of Electrostatically Actuated Microbeams with Coupled Longitudinal–Transversal Vibration
title_short Nonlinear Behavior of Electrostatically Actuated Microbeams with Coupled Longitudinal–Transversal Vibration
title_sort nonlinear behavior of electrostatically actuated microbeams with coupled longitudinal–transversal vibration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6562969/
https://www.ncbi.nlm.nih.gov/pubmed/31083425
http://dx.doi.org/10.3390/mi10050315
work_keys_str_mv AT machicheng nonlinearbehaviorofelectrostaticallyactuatedmicrobeamswithcoupledlongitudinaltransversalvibration
AT caolimin nonlinearbehaviorofelectrostaticallyactuatedmicrobeamswithcoupledlongitudinaltransversalvibration
AT lilei nonlinearbehaviorofelectrostaticallyactuatedmicrobeamswithcoupledlongitudinaltransversalvibration
AT shaomingyu nonlinearbehaviorofelectrostaticallyactuatedmicrobeamswithcoupledlongitudinaltransversalvibration
AT jingdong nonlinearbehaviorofelectrostaticallyactuatedmicrobeamswithcoupledlongitudinaltransversalvibration
AT guozonghe nonlinearbehaviorofelectrostaticallyactuatedmicrobeamswithcoupledlongitudinaltransversalvibration