Cargando…

Biomechanical Analysis of Two Types of Humerus Supracondylar Fracture Fixation in Anatomical Model

Objective  To analyze the stability of humerus supracondylar fracture fixation with Kirschner wires comparing intramedullary and lateral (Fi), and two parallel lateral wires (FL) fixation in experimental models, to define which configuration presents greater stability. Methods  A total of 72 synthet...

Descripción completa

Detalles Bibliográficos
Autores principales: Nunes, Marcos Ceita, Posser, Ticiano Dozza, Israel, Charles Leonardo, Spinelli, Leandro de Freitas, Calieron, Luis Gustavo, Kim, Jung Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Ortopedia e Traumatologia. Published by Thieme Revnter Publicações Ltda 2019
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6597430/
https://www.ncbi.nlm.nih.gov/pubmed/31363279
http://dx.doi.org/10.1055/s-0039-1688756