Machine Perfusion of Liver Grafts With Implantable Oxygen Biosensors: Proof of Concept Study in a Rodent Model

BACKGROUND. Normothermic machine perfusion (NMP) is emerging as a novel preservation strategy in liver transplantation, but the optimal methods for assessing liver grafts during this period have not been determined. The aim of this study was to investigate whether implantable oxygen biosensors can b...

Descripción completa

Detalles Bibliográficos
Autores principales: Scheuermann, Uwe, Ibrahim, Mohamed M., Yerxa, John, Parker, William, Hartwig, Matthew G., Klitzman, Bruce, Barbas, Andrew S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6616145/
https://www.ncbi.nlm.nih.gov/pubmed/31334337
http://dx.doi.org/10.1097/TXD.0000000000000905