Pure SH1 Guided-Wave Generation Method with Dual Periodic-Permanent-Magnet Electromagnetic Acoustic Transducers for Plates Inspection

High frequency guided-waves offer a trade-off between the high sensitivity of local bulk ultrasonic thickness measurements and the large area scanning of lower frequency guided-waves, so it has been a growing interest for corrosion inspection with the dispersive SH1 mode. However, according to the d...