Cargando…

The effect of the subcritical fluid extraction on the quality of almond oils: Compared to conventional mechanical pressing method

This study investigated the effect of different almond oil extraction techniques, namely, cold‐press extraction (CP), hydraulic press extraction (HP), and subcritical fluid extraction (SFE), on the fatty acid composition, physicochemical properties, bioactive substances, and thermal stability. The r...

Descripción completa

Detalles Bibliográficos
Autores principales: Qi, Zhou, Xiao, Jia, Ye, Liu, Chuyun, Wan, Chang, Zheng, Shugang, Li, Fenghong, Huang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6668568/
https://www.ncbi.nlm.nih.gov/pubmed/31388415
http://dx.doi.org/10.1002/fsn3.1023
_version_ 1783440243536429056
author Qi, Zhou
Xiao, Jia
Ye, Liu
Chuyun, Wan
Chang, Zheng
Shugang, Li
Fenghong, Huang
author_facet Qi, Zhou
Xiao, Jia
Ye, Liu
Chuyun, Wan
Chang, Zheng
Shugang, Li
Fenghong, Huang
author_sort Qi, Zhou
collection PubMed
description This study investigated the effect of different almond oil extraction techniques, namely, cold‐press extraction (CP), hydraulic press extraction (HP), and subcritical fluid extraction (SFE), on the fatty acid composition, physicochemical properties, bioactive substances, and thermal stability. The results showed that oleic acid and linoleic acid were the main unsaturated fatty acids in almond oil (AO). The overall physicochemical properties of the AO (SFE) had the better oil quality compared to cold‐press extraction and hydraulic press extraction in three kinds of varieties. Almond oil extracted from SFE contained the highest levels of total phenolics (9.58–11.75 mg/100 g), total phytosterols (92.86–244.21 mg/100 g), total tocopherols, and tocotrienols (48.03–55.74 mg/100 g). Meanwhile, the TG/DTG curves showed AO (SFE) were more thermally stable than AO (CP) and AO (HP) consistent with the result of oxidative induction time. Subcritical fluid extraction may be a useful extraction technology to produce high‐quality almond oils in the future.
format Online
Article
Text
id pubmed-6668568
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-66685682019-08-06 The effect of the subcritical fluid extraction on the quality of almond oils: Compared to conventional mechanical pressing method Qi, Zhou Xiao, Jia Ye, Liu Chuyun, Wan Chang, Zheng Shugang, Li Fenghong, Huang Food Sci Nutr Original Research This study investigated the effect of different almond oil extraction techniques, namely, cold‐press extraction (CP), hydraulic press extraction (HP), and subcritical fluid extraction (SFE), on the fatty acid composition, physicochemical properties, bioactive substances, and thermal stability. The results showed that oleic acid and linoleic acid were the main unsaturated fatty acids in almond oil (AO). The overall physicochemical properties of the AO (SFE) had the better oil quality compared to cold‐press extraction and hydraulic press extraction in three kinds of varieties. Almond oil extracted from SFE contained the highest levels of total phenolics (9.58–11.75 mg/100 g), total phytosterols (92.86–244.21 mg/100 g), total tocopherols, and tocotrienols (48.03–55.74 mg/100 g). Meanwhile, the TG/DTG curves showed AO (SFE) were more thermally stable than AO (CP) and AO (HP) consistent with the result of oxidative induction time. Subcritical fluid extraction may be a useful extraction technology to produce high‐quality almond oils in the future. John Wiley and Sons Inc. 2019-06-27 /pmc/articles/PMC6668568/ /pubmed/31388415 http://dx.doi.org/10.1002/fsn3.1023 Text en © 2019 The Authors. Food Science & Nutrition published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Qi, Zhou
Xiao, Jia
Ye, Liu
Chuyun, Wan
Chang, Zheng
Shugang, Li
Fenghong, Huang
The effect of the subcritical fluid extraction on the quality of almond oils: Compared to conventional mechanical pressing method
title The effect of the subcritical fluid extraction on the quality of almond oils: Compared to conventional mechanical pressing method
title_full The effect of the subcritical fluid extraction on the quality of almond oils: Compared to conventional mechanical pressing method
title_fullStr The effect of the subcritical fluid extraction on the quality of almond oils: Compared to conventional mechanical pressing method
title_full_unstemmed The effect of the subcritical fluid extraction on the quality of almond oils: Compared to conventional mechanical pressing method
title_short The effect of the subcritical fluid extraction on the quality of almond oils: Compared to conventional mechanical pressing method
title_sort effect of the subcritical fluid extraction on the quality of almond oils: compared to conventional mechanical pressing method
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6668568/
https://www.ncbi.nlm.nih.gov/pubmed/31388415
http://dx.doi.org/10.1002/fsn3.1023
work_keys_str_mv AT qizhou theeffectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT xiaojia theeffectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT yeliu theeffectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT chuyunwan theeffectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT changzheng theeffectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT shugangli theeffectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT fenghonghuang theeffectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT qizhou effectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT xiaojia effectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT yeliu effectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT chuyunwan effectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT changzheng effectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT shugangli effectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod
AT fenghonghuang effectofthesubcriticalfluidextractiononthequalityofalmondoilscomparedtoconventionalmechanicalpressingmethod