Cargando…

Two Degree-of-Freedom Fiber-Coupled Heterodyne Grating Interferometer with Milli-Radian Operating Range of Rotation

In the displacement measurement of the wafer stage in lithography machines, signal quality is affected by the relative angular position between the encoder head and the grating. In this study, a two-degree-of-freedom fiber-coupled heterodyne grating interferometer with large operating range of rotat...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Fuzhong, Zhang, Ming, Zhu, Yu, Ye, Weinan, Wang, Leijie, Xia, Yizhou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679590/
https://www.ncbi.nlm.nih.gov/pubmed/31336608
http://dx.doi.org/10.3390/s19143219
_version_ 1783441369629458432
author Yang, Fuzhong
Zhang, Ming
Zhu, Yu
Ye, Weinan
Wang, Leijie
Xia, Yizhou
author_facet Yang, Fuzhong
Zhang, Ming
Zhu, Yu
Ye, Weinan
Wang, Leijie
Xia, Yizhou
author_sort Yang, Fuzhong
collection PubMed
description In the displacement measurement of the wafer stage in lithography machines, signal quality is affected by the relative angular position between the encoder head and the grating. In this study, a two-degree-of-freedom fiber-coupled heterodyne grating interferometer with large operating range of rotation is presented. Fibers without fiber couplers are utilized to receive the interference beams for high-contrast signals under the circumstances of large angular displacement and ZEMAX ray tracing software simulation and experimental validation have been carried out. Meanwhile, a reference beam generated inside the encoder head is adopted to suppress the thermal drift of the interferometer. Experimental results prove that the proposed grating interferometer could realize sub-nanometer displacement measurement stability in both in-plane and out-of-plane directions, which is 0.246 nm and 0.465 nm of 3σ value respectively within 30 s.
format Online
Article
Text
id pubmed-6679590
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66795902019-08-19 Two Degree-of-Freedom Fiber-Coupled Heterodyne Grating Interferometer with Milli-Radian Operating Range of Rotation Yang, Fuzhong Zhang, Ming Zhu, Yu Ye, Weinan Wang, Leijie Xia, Yizhou Sensors (Basel) Article In the displacement measurement of the wafer stage in lithography machines, signal quality is affected by the relative angular position between the encoder head and the grating. In this study, a two-degree-of-freedom fiber-coupled heterodyne grating interferometer with large operating range of rotation is presented. Fibers without fiber couplers are utilized to receive the interference beams for high-contrast signals under the circumstances of large angular displacement and ZEMAX ray tracing software simulation and experimental validation have been carried out. Meanwhile, a reference beam generated inside the encoder head is adopted to suppress the thermal drift of the interferometer. Experimental results prove that the proposed grating interferometer could realize sub-nanometer displacement measurement stability in both in-plane and out-of-plane directions, which is 0.246 nm and 0.465 nm of 3σ value respectively within 30 s. MDPI 2019-07-22 /pmc/articles/PMC6679590/ /pubmed/31336608 http://dx.doi.org/10.3390/s19143219 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yang, Fuzhong
Zhang, Ming
Zhu, Yu
Ye, Weinan
Wang, Leijie
Xia, Yizhou
Two Degree-of-Freedom Fiber-Coupled Heterodyne Grating Interferometer with Milli-Radian Operating Range of Rotation
title Two Degree-of-Freedom Fiber-Coupled Heterodyne Grating Interferometer with Milli-Radian Operating Range of Rotation
title_full Two Degree-of-Freedom Fiber-Coupled Heterodyne Grating Interferometer with Milli-Radian Operating Range of Rotation
title_fullStr Two Degree-of-Freedom Fiber-Coupled Heterodyne Grating Interferometer with Milli-Radian Operating Range of Rotation
title_full_unstemmed Two Degree-of-Freedom Fiber-Coupled Heterodyne Grating Interferometer with Milli-Radian Operating Range of Rotation
title_short Two Degree-of-Freedom Fiber-Coupled Heterodyne Grating Interferometer with Milli-Radian Operating Range of Rotation
title_sort two degree-of-freedom fiber-coupled heterodyne grating interferometer with milli-radian operating range of rotation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679590/
https://www.ncbi.nlm.nih.gov/pubmed/31336608
http://dx.doi.org/10.3390/s19143219
work_keys_str_mv AT yangfuzhong twodegreeoffreedomfibercoupledheterodynegratinginterferometerwithmilliradianoperatingrangeofrotation
AT zhangming twodegreeoffreedomfibercoupledheterodynegratinginterferometerwithmilliradianoperatingrangeofrotation
AT zhuyu twodegreeoffreedomfibercoupledheterodynegratinginterferometerwithmilliradianoperatingrangeofrotation
AT yeweinan twodegreeoffreedomfibercoupledheterodynegratinginterferometerwithmilliradianoperatingrangeofrotation
AT wangleijie twodegreeoffreedomfibercoupledheterodynegratinginterferometerwithmilliradianoperatingrangeofrotation
AT xiayizhou twodegreeoffreedomfibercoupledheterodynegratinginterferometerwithmilliradianoperatingrangeofrotation