Cargando…

Helical blade compression failure occurred during PFNA implantation: A rare case and ingenious solution

RATIONALE: Femoral intertrochanteric fracture happens easily in the elderly, especially those with osteoporosis. As a standard intramedullary fixation implant, Proximal Femoral Nail Anti-rotation (PFNA) is applied to various types of stable or unstable intertrochanteric fractures of femur. Due to bl...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Chaoqun, Wang, Qingxian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6709006/
https://www.ncbi.nlm.nih.gov/pubmed/31348296
http://dx.doi.org/10.1097/MD.0000000000016584
_version_ 1783446108785082368
author Wang, Chaoqun
Wang, Qingxian
author_facet Wang, Chaoqun
Wang, Qingxian
author_sort Wang, Chaoqun
collection PubMed
description RATIONALE: Femoral intertrochanteric fracture happens easily in the elderly, especially those with osteoporosis. As a standard intramedullary fixation implant, Proximal Femoral Nail Anti-rotation (PFNA) is applied to various types of stable or unstable intertrochanteric fractures of femur. Due to blade-related factors, such as cutting-through into the hip joint, cutting out or back out, there are endless postoperative failure cases of internal fixation, but reports about perioperative failure that the helical blade cannot be tightened are lacking. In this case, we firstly report an intraoperative blade compression failure and an effective technique to help surgeons out of the dilemma by using cannulated hexagonal screwdriver which was already included in the orthopedic instrument box. PATIENT CONCERNS: An 81-year-old lady suffered left hip pain, swelling and limitation of activity, after slipping and falling when she was in the toilet. DIAGNOSES: X-ray and computed tomography (CT)-scan showed comminuted left intratrochanteric fracture with a Jensen classification of IIa type. INTERVENTIONS: The patient was treated by closed reduction and internal fixation with PFNA. We suffered an unprecedented problem that helical blade cannot be tightened by the blade impactor as usual. For fear of helical blade disintegration during removal and a significant decrease in pullout strength after reinsertions, we eliminated the dilemma by using a cannulated hexagonal screwdriver to tighten the “problem” helical blade. OUTCOMES: The “problem” helical blade was finally locked by using the SW4.0 mm cannulated hexagonal screwdriver which was already included in the instrument box. The operation ended successfully after completing subsequent steps. LESSONS: The cannulated hexagonal screwdriver is an effective instrument that can help surgeons out of the dilemma when the blade impactor fails to tighten the helical blade in PFNA implantation.
format Online
Article
Text
id pubmed-6709006
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-67090062019-10-01 Helical blade compression failure occurred during PFNA implantation: A rare case and ingenious solution Wang, Chaoqun Wang, Qingxian Medicine (Baltimore) Research Article RATIONALE: Femoral intertrochanteric fracture happens easily in the elderly, especially those with osteoporosis. As a standard intramedullary fixation implant, Proximal Femoral Nail Anti-rotation (PFNA) is applied to various types of stable or unstable intertrochanteric fractures of femur. Due to blade-related factors, such as cutting-through into the hip joint, cutting out or back out, there are endless postoperative failure cases of internal fixation, but reports about perioperative failure that the helical blade cannot be tightened are lacking. In this case, we firstly report an intraoperative blade compression failure and an effective technique to help surgeons out of the dilemma by using cannulated hexagonal screwdriver which was already included in the orthopedic instrument box. PATIENT CONCERNS: An 81-year-old lady suffered left hip pain, swelling and limitation of activity, after slipping and falling when she was in the toilet. DIAGNOSES: X-ray and computed tomography (CT)-scan showed comminuted left intratrochanteric fracture with a Jensen classification of IIa type. INTERVENTIONS: The patient was treated by closed reduction and internal fixation with PFNA. We suffered an unprecedented problem that helical blade cannot be tightened by the blade impactor as usual. For fear of helical blade disintegration during removal and a significant decrease in pullout strength after reinsertions, we eliminated the dilemma by using a cannulated hexagonal screwdriver to tighten the “problem” helical blade. OUTCOMES: The “problem” helical blade was finally locked by using the SW4.0 mm cannulated hexagonal screwdriver which was already included in the instrument box. The operation ended successfully after completing subsequent steps. LESSONS: The cannulated hexagonal screwdriver is an effective instrument that can help surgeons out of the dilemma when the blade impactor fails to tighten the helical blade in PFNA implantation. Wolters Kluwer Health 2019-07-26 /pmc/articles/PMC6709006/ /pubmed/31348296 http://dx.doi.org/10.1097/MD.0000000000016584 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle Research Article
Wang, Chaoqun
Wang, Qingxian
Helical blade compression failure occurred during PFNA implantation: A rare case and ingenious solution
title Helical blade compression failure occurred during PFNA implantation: A rare case and ingenious solution
title_full Helical blade compression failure occurred during PFNA implantation: A rare case and ingenious solution
title_fullStr Helical blade compression failure occurred during PFNA implantation: A rare case and ingenious solution
title_full_unstemmed Helical blade compression failure occurred during PFNA implantation: A rare case and ingenious solution
title_short Helical blade compression failure occurred during PFNA implantation: A rare case and ingenious solution
title_sort helical blade compression failure occurred during pfna implantation: a rare case and ingenious solution
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6709006/
https://www.ncbi.nlm.nih.gov/pubmed/31348296
http://dx.doi.org/10.1097/MD.0000000000016584
work_keys_str_mv AT wangchaoqun helicalbladecompressionfailureoccurredduringpfnaimplantationararecaseandingenioussolution
AT wangqingxian helicalbladecompressionfailureoccurredduringpfnaimplantationararecaseandingenioussolution