Systemic Oxygen Delivery during One-Lung Ventilation: Comparison between Propofol and Sevoflurane Anaesthesia in a Randomised Controlled Trial

Systemic oxygen delivery (DO(2)) is a more comprehensive marker of patient status than arterial oxygen saturation (SaO(2)), and DO(2) in the range of 330–500 mL min(−1) is reportedly adequate during anaesthesia. We measured DO(2) during one-lung ventilation (OLV) for thoracic surgery—where the risk...