Analysis of crystallization fouling in electric water heating

In the present study, the main influencing factors of crystallization fouling in electric water heating were investigated. Dependence on the saturation index and four operating parameters was analyzed, namely: liquid temperature, surface temperature, flow rate and electrical leakage current. A focus...