Cargando…

Assessment of the AQUIOS flow cytometer – An automated sample preparation system for CD4 lymphocyte PanLeucogating enumeration

BACKGROUND: Flow cytometry has been the approach of choice for enumerating and documenting CD4-cell decline in HIV monitoring. Beckman Coulter has developed a single platform test for CD4+ T-cell lymphocyte count and percentage using PanLeucogating (PLG) technology on the automated AQUIOS flow cytom...

Descripción completa

Detalles Bibliográficos
Autores principales: Rhodes, Daniel, Carcelain, Guislaine, Keeney, Mike, Parizot, Christophe, Benjamins, Dominika, Genesta, Laurine, Zhang, Jin, Rohrbach, Justin, Lawrie, Denise, Glencross, Deborah K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AOSIS 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6909423/
https://www.ncbi.nlm.nih.gov/pubmed/31850159
http://dx.doi.org/10.4102/ajlm.v8i1.804
_version_ 1783478936649334784
author Rhodes, Daniel
Carcelain, Guislaine
Keeney, Mike
Parizot, Christophe
Benjamins, Dominika
Genesta, Laurine
Zhang, Jin
Rohrbach, Justin
Lawrie, Denise
Glencross, Deborah K.
author_facet Rhodes, Daniel
Carcelain, Guislaine
Keeney, Mike
Parizot, Christophe
Benjamins, Dominika
Genesta, Laurine
Zhang, Jin
Rohrbach, Justin
Lawrie, Denise
Glencross, Deborah K.
author_sort Rhodes, Daniel
collection PubMed
description BACKGROUND: Flow cytometry has been the approach of choice for enumerating and documenting CD4-cell decline in HIV monitoring. Beckman Coulter has developed a single platform test for CD4+ T-cell lymphocyte count and percentage using PanLeucogating (PLG) technology on the automated AQUIOS flow cytometer (AQUIOS PLG). OBJECTIVES: This study compared the performance of AQUIOS PLG with the Flowcare PLG method and performed a reference interval for comparison with those previously published. METHODS: The study was conducted between November 2014 and March 2015 at 5 different centres located in Canada; Paris, France; Lyon, France; the United States; and South Africa. Two-hundred and forty samples from HIV-positive adult and paediatric patients were used to compare the performances of AQUIOS PLG and Flowcare PLG on a FC500 flow cytometer (Flowcare PLG) in determining CD4+ absolute count and percentage. A reference interval was determined using 155 samples from healthy, non-HIV adults. Workflow was investigated testing 440 samples over 5 days. RESULTS: Mean absolute and relative count bias between AQUIOS PLG and Flowcare PLG was −41 cells/µL and −7.8%. Upward and downward misclassification at various CD4 thresholds was ≤ 2.4% and ≤ 11.1%. The 95% reference interval (2.5th – 97.5th) for the CD4+ count was 453–1534 cells/µL and the percentage was 30.5% – 63.4%. The workflow showed an average number of HIV samples tested as 17.5 per hour or 122.5 per 8-hour shift for one technician, including passing quality controls. CONCLUSION: The AQUIOS PLG merges desirable aspects from conventional flow cytometer systems (high throughput, precision and accuracy, external quality assessment compatibility) with low technical operating skill requirements for automated, single platform systems.
format Online
Article
Text
id pubmed-6909423
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher AOSIS
record_format MEDLINE/PubMed
spelling pubmed-69094232019-12-17 Assessment of the AQUIOS flow cytometer – An automated sample preparation system for CD4 lymphocyte PanLeucogating enumeration Rhodes, Daniel Carcelain, Guislaine Keeney, Mike Parizot, Christophe Benjamins, Dominika Genesta, Laurine Zhang, Jin Rohrbach, Justin Lawrie, Denise Glencross, Deborah K. Afr J Lab Med Original Research BACKGROUND: Flow cytometry has been the approach of choice for enumerating and documenting CD4-cell decline in HIV monitoring. Beckman Coulter has developed a single platform test for CD4+ T-cell lymphocyte count and percentage using PanLeucogating (PLG) technology on the automated AQUIOS flow cytometer (AQUIOS PLG). OBJECTIVES: This study compared the performance of AQUIOS PLG with the Flowcare PLG method and performed a reference interval for comparison with those previously published. METHODS: The study was conducted between November 2014 and March 2015 at 5 different centres located in Canada; Paris, France; Lyon, France; the United States; and South Africa. Two-hundred and forty samples from HIV-positive adult and paediatric patients were used to compare the performances of AQUIOS PLG and Flowcare PLG on a FC500 flow cytometer (Flowcare PLG) in determining CD4+ absolute count and percentage. A reference interval was determined using 155 samples from healthy, non-HIV adults. Workflow was investigated testing 440 samples over 5 days. RESULTS: Mean absolute and relative count bias between AQUIOS PLG and Flowcare PLG was −41 cells/µL and −7.8%. Upward and downward misclassification at various CD4 thresholds was ≤ 2.4% and ≤ 11.1%. The 95% reference interval (2.5th – 97.5th) for the CD4+ count was 453–1534 cells/µL and the percentage was 30.5% – 63.4%. The workflow showed an average number of HIV samples tested as 17.5 per hour or 122.5 per 8-hour shift for one technician, including passing quality controls. CONCLUSION: The AQUIOS PLG merges desirable aspects from conventional flow cytometer systems (high throughput, precision and accuracy, external quality assessment compatibility) with low technical operating skill requirements for automated, single platform systems. AOSIS 2019-12-05 /pmc/articles/PMC6909423/ /pubmed/31850159 http://dx.doi.org/10.4102/ajlm.v8i1.804 Text en © 2019. The Authors https://creativecommons.org/licenses/by/4.0/ Licensee: AOSIS. This work is licensed under the Creative Commons Attribution License.
spellingShingle Original Research
Rhodes, Daniel
Carcelain, Guislaine
Keeney, Mike
Parizot, Christophe
Benjamins, Dominika
Genesta, Laurine
Zhang, Jin
Rohrbach, Justin
Lawrie, Denise
Glencross, Deborah K.
Assessment of the AQUIOS flow cytometer – An automated sample preparation system for CD4 lymphocyte PanLeucogating enumeration
title Assessment of the AQUIOS flow cytometer – An automated sample preparation system for CD4 lymphocyte PanLeucogating enumeration
title_full Assessment of the AQUIOS flow cytometer – An automated sample preparation system for CD4 lymphocyte PanLeucogating enumeration
title_fullStr Assessment of the AQUIOS flow cytometer – An automated sample preparation system for CD4 lymphocyte PanLeucogating enumeration
title_full_unstemmed Assessment of the AQUIOS flow cytometer – An automated sample preparation system for CD4 lymphocyte PanLeucogating enumeration
title_short Assessment of the AQUIOS flow cytometer – An automated sample preparation system for CD4 lymphocyte PanLeucogating enumeration
title_sort assessment of the aquios flow cytometer – an automated sample preparation system for cd4 lymphocyte panleucogating enumeration
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6909423/
https://www.ncbi.nlm.nih.gov/pubmed/31850159
http://dx.doi.org/10.4102/ajlm.v8i1.804
work_keys_str_mv AT rhodesdaniel assessmentoftheaquiosflowcytometeranautomatedsamplepreparationsystemforcd4lymphocytepanleucogatingenumeration
AT carcelainguislaine assessmentoftheaquiosflowcytometeranautomatedsamplepreparationsystemforcd4lymphocytepanleucogatingenumeration
AT keeneymike assessmentoftheaquiosflowcytometeranautomatedsamplepreparationsystemforcd4lymphocytepanleucogatingenumeration
AT parizotchristophe assessmentoftheaquiosflowcytometeranautomatedsamplepreparationsystemforcd4lymphocytepanleucogatingenumeration
AT benjaminsdominika assessmentoftheaquiosflowcytometeranautomatedsamplepreparationsystemforcd4lymphocytepanleucogatingenumeration
AT genestalaurine assessmentoftheaquiosflowcytometeranautomatedsamplepreparationsystemforcd4lymphocytepanleucogatingenumeration
AT zhangjin assessmentoftheaquiosflowcytometeranautomatedsamplepreparationsystemforcd4lymphocytepanleucogatingenumeration
AT rohrbachjustin assessmentoftheaquiosflowcytometeranautomatedsamplepreparationsystemforcd4lymphocytepanleucogatingenumeration
AT lawriedenise assessmentoftheaquiosflowcytometeranautomatedsamplepreparationsystemforcd4lymphocytepanleucogatingenumeration
AT glencrossdeborahk assessmentoftheaquiosflowcytometeranautomatedsamplepreparationsystemforcd4lymphocytepanleucogatingenumeration