Cargando…
Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases
Carvedilol is a chiral drug with potent antihypertensive and antianginal activities. Although it is clinically used as a racemic mixture, its enantiomers show different pharmacokinetic and pharmacodynamic profiles. Here, the direct chiral separation of racemic drug by high performance liquid chromat...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Xi'an Jiaotong University
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6951491/ https://www.ncbi.nlm.nih.gov/pubmed/31929941 http://dx.doi.org/10.1016/j.jpha.2019.04.002 |
_version_ | 1783486283552653312 |
---|---|
author | Panella, Cristina Ferretti, Rosella Casulli, Adriano Cirilli, Roberto |
author_facet | Panella, Cristina Ferretti, Rosella Casulli, Adriano Cirilli, Roberto |
author_sort | Panella, Cristina |
collection | PubMed |
description | Carvedilol is a chiral drug with potent antihypertensive and antianginal activities. Although it is clinically used as a racemic mixture, its enantiomers show different pharmacokinetic and pharmacodynamic profiles. Here, the direct chiral separation of racemic drug by high performance liquid chromatography using two immobilized-type amylose-based chiral stationary phases is presented. Some chromatographic parameters, such as retention and selectivity, were determined under multimodal eluent conditions and different temperatures. A temperature-dependent inversion of the elution order of enantiomers was observed in the operative temperature range of chiral chromatographic support. Finally, an effective direct enantioselective method was successfully applied to the separation of the enantiomers of carvedilol on a semipreparative scale. |
format | Online Article Text |
id | pubmed-6951491 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Xi'an Jiaotong University |
record_format | MEDLINE/PubMed |
spelling | pubmed-69514912020-01-10 Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases Panella, Cristina Ferretti, Rosella Casulli, Adriano Cirilli, Roberto J Pharm Anal Article Carvedilol is a chiral drug with potent antihypertensive and antianginal activities. Although it is clinically used as a racemic mixture, its enantiomers show different pharmacokinetic and pharmacodynamic profiles. Here, the direct chiral separation of racemic drug by high performance liquid chromatography using two immobilized-type amylose-based chiral stationary phases is presented. Some chromatographic parameters, such as retention and selectivity, were determined under multimodal eluent conditions and different temperatures. A temperature-dependent inversion of the elution order of enantiomers was observed in the operative temperature range of chiral chromatographic support. Finally, an effective direct enantioselective method was successfully applied to the separation of the enantiomers of carvedilol on a semipreparative scale. Xi'an Jiaotong University 2019-10 2019-04-04 /pmc/articles/PMC6951491/ /pubmed/31929941 http://dx.doi.org/10.1016/j.jpha.2019.04.002 Text en © 2019 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Panella, Cristina Ferretti, Rosella Casulli, Adriano Cirilli, Roberto Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases |
title | Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases |
title_full | Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases |
title_fullStr | Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases |
title_full_unstemmed | Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases |
title_short | Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases |
title_sort | temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6951491/ https://www.ncbi.nlm.nih.gov/pubmed/31929941 http://dx.doi.org/10.1016/j.jpha.2019.04.002 |
work_keys_str_mv | AT panellacristina temperatureandeluentcompositioneffectsonenantiomerseparationofcarvedilolbyhighperformanceliquidchromatographyonimmobilizedamylosebasedchiralstationaryphases AT ferrettirosella temperatureandeluentcompositioneffectsonenantiomerseparationofcarvedilolbyhighperformanceliquidchromatographyonimmobilizedamylosebasedchiralstationaryphases AT casulliadriano temperatureandeluentcompositioneffectsonenantiomerseparationofcarvedilolbyhighperformanceliquidchromatographyonimmobilizedamylosebasedchiralstationaryphases AT cirilliroberto temperatureandeluentcompositioneffectsonenantiomerseparationofcarvedilolbyhighperformanceliquidchromatographyonimmobilizedamylosebasedchiralstationaryphases |