Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases

Carvedilol is a chiral drug with potent antihypertensive and antianginal activities. Although it is clinically used as a racemic mixture, its enantiomers show different pharmacokinetic and pharmacodynamic profiles. Here, the direct chiral separation of racemic drug by high performance liquid chromat...

Descripción completa

Detalles Bibliográficos
Autores principales: Panella, Cristina, Ferretti, Rosella, Casulli, Adriano, Cirilli, Roberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6951491/
https://www.ncbi.nlm.nih.gov/pubmed/31929941
http://dx.doi.org/10.1016/j.jpha.2019.04.002
_version_ 1783486283552653312
author Panella, Cristina
Ferretti, Rosella
Casulli, Adriano
Cirilli, Roberto
author_facet Panella, Cristina
Ferretti, Rosella
Casulli, Adriano
Cirilli, Roberto
author_sort Panella, Cristina
collection PubMed
description Carvedilol is a chiral drug with potent antihypertensive and antianginal activities. Although it is clinically used as a racemic mixture, its enantiomers show different pharmacokinetic and pharmacodynamic profiles. Here, the direct chiral separation of racemic drug by high performance liquid chromatography using two immobilized-type amylose-based chiral stationary phases is presented. Some chromatographic parameters, such as retention and selectivity, were determined under multimodal eluent conditions and different temperatures. A temperature-dependent inversion of the elution order of enantiomers was observed in the operative temperature range of chiral chromatographic support. Finally, an effective direct enantioselective method was successfully applied to the separation of the enantiomers of carvedilol on a semipreparative scale.
format Online
Article
Text
id pubmed-6951491
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-69514912020-01-10 Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases Panella, Cristina Ferretti, Rosella Casulli, Adriano Cirilli, Roberto J Pharm Anal Article Carvedilol is a chiral drug with potent antihypertensive and antianginal activities. Although it is clinically used as a racemic mixture, its enantiomers show different pharmacokinetic and pharmacodynamic profiles. Here, the direct chiral separation of racemic drug by high performance liquid chromatography using two immobilized-type amylose-based chiral stationary phases is presented. Some chromatographic parameters, such as retention and selectivity, were determined under multimodal eluent conditions and different temperatures. A temperature-dependent inversion of the elution order of enantiomers was observed in the operative temperature range of chiral chromatographic support. Finally, an effective direct enantioselective method was successfully applied to the separation of the enantiomers of carvedilol on a semipreparative scale. Xi'an Jiaotong University 2019-10 2019-04-04 /pmc/articles/PMC6951491/ /pubmed/31929941 http://dx.doi.org/10.1016/j.jpha.2019.04.002 Text en © 2019 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Panella, Cristina
Ferretti, Rosella
Casulli, Adriano
Cirilli, Roberto
Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases
title Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases
title_full Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases
title_fullStr Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases
title_full_unstemmed Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases
title_short Temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases
title_sort temperature and eluent composition effects on enantiomer separation of carvedilol by high-performance liquid chromatography on immobilized amylose-based chiral stationary phases
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6951491/
https://www.ncbi.nlm.nih.gov/pubmed/31929941
http://dx.doi.org/10.1016/j.jpha.2019.04.002
work_keys_str_mv AT panellacristina temperatureandeluentcompositioneffectsonenantiomerseparationofcarvedilolbyhighperformanceliquidchromatographyonimmobilizedamylosebasedchiralstationaryphases
AT ferrettirosella temperatureandeluentcompositioneffectsonenantiomerseparationofcarvedilolbyhighperformanceliquidchromatographyonimmobilizedamylosebasedchiralstationaryphases
AT casulliadriano temperatureandeluentcompositioneffectsonenantiomerseparationofcarvedilolbyhighperformanceliquidchromatographyonimmobilizedamylosebasedchiralstationaryphases
AT cirilliroberto temperatureandeluentcompositioneffectsonenantiomerseparationofcarvedilolbyhighperformanceliquidchromatographyonimmobilizedamylosebasedchiralstationaryphases