Image intensification - A solution for difficult guidewire insertion for central venous access: A case report
PRESENTATION OF CASE: A 56-year old male presented for an elective redo-sternotomy, aortic valve replacement, tricuspid valve annuloplasty, and coronary artery bypass grafting. During central vascular access using a standard Seldinger technique, resistance to two spring-wire guide wires was encounte...